<1.  Introduction>

1

IM 01E21A01-03EN-A

1st Edition: Mar. 2020 (KP)

All Rights Reserved, Copyright © 2020, Yokogawa Electric Corporation

1. 

Introduction

This manual provides the basic guidelines for installation, 
wiring procedures and basic operation of ADMAG TI (Total 
Insight) Series AXG magnetic flowmeters with EtherNet/IP 

protocol.

For the items which are not covered in this manual,
read the applicable user’s manuals and general
specifications as listed in Table 1.1. These documents can 
be downloaded from the YOKOGAWA website. To ensure 
correct use of the product, read these manuals thoroughly 
and fully understand how to operate the product before 
operating it. For method of checking the model and 
specifications, read Chapter 2 and general specifications 

as listed in Table 1.1.

Website address: http://www.yokogawa.com/fld/doc/
These manuals can be downloaded from the website 
of YOKOGAWA or purchased from the YOKOGAWA 

representatives.

Table 1.1

    Manual and General Specifications List

Model

Document Title

Document No.

AXG###
AXG4A

ADMAG TI Series
AXG###, AXG4A Magnetic 

Flowmeter

EtherNet/IP communication type

Read Me First

IM 01E21A21-
04EN-A

ADMAG TI Series
AXG Magnetic Flowmeter
Installation Manual

IM 01E22A01-01EN

ADMAG TI Series
AXG Magnetic Flowmeter
EtherNet/IP Communication Type
Installation Manual 
Difference to IM 01E22A01-01EN

IM 01E21A01-03EN-A 
(this manual)

ADMAG TI Series
AXG Magnetic Flowmeter

Maintenance Manual

IM 01E22A01-02EN

ADMAG TI Series
AXG Magnetic Flowmeter
General Specification

GS 01E22A01-01EN

ADMAG TI Series
AXG Magnetic Flowmeter
EtherNet/IP Communication Type

IM 01E21A02-06EN

ADMAG TI Series 
AXG Magnetic Flowmeter
EtherNet/IP Communication Type

GS 01E21F02-02EN-A

NOTE

When describing the model name like AXG### in this 
manual, “###” means any of the following.
002, 005, 010, 015, 025, 040, 050, 080, 100, 150, 200

„

  Precautions Related to the Protection, 

Safety, and Alteration of the Product

(Please read the descriptions on IM 01E22A01-01EN.)

„

  Regarding This User’s Manual

(Please read the descriptions on IM 01E22A01-01EN.)

„

  Trademarks:

(Please read the descriptions on IM 01E22A01-01EN, 
and add the following description.)

•  “EtherNet/IP”, “CIP” and “ODVA” are registered 

trademark of ODVA Inc.

1.1  For Safe Use of Product

System in which this product is incorporated, be sure to 
follow the instructions and precautions on safety that is 
stated in this manual whenever you handle the product. 
Take special note that if you handle the product in a 
manner that violated these instructions, the protection 
functionality of the product may be damaged or impaired. 
In such cases, YOKOGAWA shall not be liable for any 
indirect or consequential loss incurred by either using or 
not being able to use the Product.

(1)  General

•  This product conforms to IEC safety class I (with 

Protective grounding terminal), Installation Category 
(Overvoltage Category) II, No Measurement Category 
(“O”(Other)), Micro Pollution degree 2, Macro 
Pollution degree 4, Altitude at installation Site Max. 

2000 m above sea level.

•  This product is an EN61326-1 (EMC standard), Class A (for 

use in commercial, industrial, or business environments).

•  This product conforms to the standard specifications 

of CIP for EtherNet/IP communication.

•  This product is complied with IP66 and IP67 in the 

EN60529. YOKOGAWA assumes no liability for the 
customer’s failure to comply with these requirements.

•  This product is designed for indoor and outdoor use.

CAUTION

This product is a Class A product in the EN61326- 
1(EMC standard). Operation of this product in a 
residential area may cause radio interference, in 
which case the user is required to take appropriate 
measures to correct the interference.

IMPORTANT

The minimum ambient temperature is limited by the 
minimum fluid temperature of the sensor (the lining). 
For more information, read the applicable general 
specifications as listed in Table 1.1. The flowmeter 
may be used in an ambient humidity where the relative 
humidity ranges from 0 to 100%. However, avoid long-
term continuous operation at relative humidity above 
95%.

Summary of Contents for ADMAG AXG Series

Page 1: ...dbus Configuration Tool 10 5 9 FOUNDATION fieldbus Configuration Tool 11 5 10 EtherNet IP Configuration Tool 11 6 Operation 6 1 Pre operation Zero Adjustment 12 6 2 Zero Adjustment from Display Unit 12 6 3 Hardware Switch Setting 12 6 3 1 Integral Type and AXG4A Remote Transmitter 12 6 3 2 AXG1A Remote Transmitter 13 6 3 3 AXFA11 Remote Transmitter 13 7 Errors and Countermeasures Display unit ADMA...

Page 2: ...Product Please read the descriptions on IM 01E22A01 01EN Regarding This User s Manual Please read the descriptions on IM 01E22A01 01EN Trademarks Please read the descriptions on IM 01E22A01 01EN and add the following description EtherNet IP CIP and ODVA are registered trademark of ODVA Inc 1 1 For Safe Use of Product System in which this product is incorporated be sure to follow the instructions a...

Page 3: ...f the voltage specified for this product before connecting the power cable In addition check that no voltage is applied to the power cable before connecting the wiring To prevent electric shocks ensure the electrical wiring cover is completely attached after the wiring work To prevent electric shocks do not impress over rated voltage to each input output terminals If there is any unused cable entr...

Page 4: ...1 Introduction 3 IM 01E21A01 03EN A 1 2 Warranty Please read the descriptions on IM 01E22A01 01EN 1 3 Combination for Remote Sensor and Remote Transmitter Please read the descriptions on IM 01E22A01 01EN ...

Page 5: ... serial number meter factor fluid specification and device information are found on the name plate located on the outside of the housing And this product can check their information from parameters Read the user s manual of applicable communication type as listed in Table 1 1 for checking device information from parameters When checking the matching of model and specification you ordered see the a...

Page 6: ... 3 Installation 5 IM 01E21A01 03EN A 3 Installation Please read the descriptions on IM 01E22A01 01EN ...

Page 7: ... IM 01E22A01 01EN 4 4 Connecting to External Products of Integral Flowmeter and Remote Transmitter 4 4 1 Wiring Precautions for Power Supply Cables When connecting to the power supply observe the points below Failure to comply with these warnings may result in an electric shock or damage to the product WARNING Ensure that the power supply is off in order to prevent electric shocks When opening the...

Page 8: ...Integral Flowmeter and AXG4A Remote Transmitter Please read the descriptions on IM 01E22A01 01EN 2 Terminal Configuration Integral Flowmeter and AXG4A Transmitter Protective Grounding Terminal Protective Grounding Terminal Integral Flowmeter AXG4A Remote Transmitter F0402 ai Integral Type AXG4A Remote Transmitter When the cover is removed the connection terminals will be visible The description of...

Page 9: ...1 PORT2 PORT1 Link Activity PORT2 Link Activity Module Status Network Status MX The same procedure for PORT2 10 100Mbps PORT2 10 100Mbps PORT1 PORT2 PORT1 Link Activity PORT2 Link Activity Module Status Network Status MX F0407 ai AXG4A Remote Transmitter To be wired to Remote Sensor F0407 ai Terminal Symbol SA SB A B C EX1 EX2 Flow Signal Input Excitation Current Output Description Figure 4 4 3 Te...

Page 10: ...select Yes F0503 ai Setting Mode No Yes 00 00 SET SFT INC 4 Touch SET switch F0504 ai Setting Mode Yes No 00 00 SET SFT INC 5 Yes is blinking Touch SET switch again F0505 ai 00 00 SET SFT INC Setting Mode Yes 6 The screen moves to the menu of Operation Level F0506 ai Operation level Specialist Exit Operator 00 00 SET SFT INC 7 Select an appropreate operation level by moving the cursor with INC or ...

Page 11: ...low Type Example of display Contents Select type F0511 ai Unit m3 l liter cm3 00 00 SET SFT INC Select the adequate data from among alternatives which are detemined in advance Numeric type F0512 ai Span 7200 00 2200 00 0 00001 999999 00 00 SET SFT INC Specify the data with a combination of number and a decimal point into each digit Alphanumeric type F0513 ai Tag No FT 1234 FT 1234 00 00 SET SFT IN...

Page 12: ...urpose connect RJ 45 Ethernet cable without passing though the cable hole of device Web page can be used for configuration of EtherNet IP device See IM 01E21A02 06EN for details Supported software Operation systems Microsoft Windows 7 or higher Web browser Internet explorer 8 or higher Google chrome Microsoft Edge Product code name and EDS file for EtherNet IP EDS file is required to connect host ...

Page 13: ...it and the cables except the setting switches When installing the cover in order to contact the housing and the cover be sure to screw it firmly into the housing without any space between them 1 Remove the cover 2 While holding the display by hand loosen the two mounting screws 3 While holding the display by hand careful for connecting cable set the switches Never remove connector in this case Saf...

Page 14: ...ss switch Position of Switch Description 1 0 3 2 5 4 7 6 0 1 ADDRESS Setting range 1 to 244 If all switches are set to OFF or ON the device IP address 4th octet is automatically converted to 210 Setting example If only the address switch position 7 is set to 1 the device IP address 4th octet is 128 1 27 0 26 0 25 0 24 0 23 0 22 0 21 0 20 Setting Enable Hardware Address Switch SW3 1 This switch is ...

Page 15: ...erNet IP board was detected Contact Yokogawa service center F 201 Opt bd comm ERR2 Communication error of EtherNet IP board was detected Contact Yokogawa service center Process Alarm Please read the descriptions on IM 01E22A01 01EN Setting Alarm Please read the descriptions on IM 01E22A01 01EN Warning Please read the descriptions on IM 01E22A01 01EN Information Please read the descriptions on IM 0...

Page 16: ... Information z Title ADMAG TI Series AXG Magnetic Flowmeter EtherNet IP Communication Type Installation Manual Difference to IM 01E22A01 01EN z Manual No IM 01E21A01 03EN A Edition Date Page Revised Item 1st Mar 2020 New publication ...

Reviews: