10
IM 701928-01E
Compliant Standards
Model
PBC100 (701928)/PBC050 (701929)
Safety standards
EN 61010-1
EN 61010-2-032 Type D
Pollution degree 2 *
1
EMC
standards
Emissions
EN 61326-1 Class B
EN 55011 Class B Group 1
EMC Regulatory Arrangement in Australia and New Zealand
EN 55011 Class B Group 1
Immunity
EN 61326-1 Table 1 (Basic immunity requirement)
Environmental standards*
2
EU RoHS Directive compliant
*1 Pollution degree applies to the degree of adhesion of a solid, liquid, or gas which
deteriorates withstand voltage or surface resistivity. Pollution degree 2 applies to
normal indoor atmospheres (usually with only non-conductive pollution).
*2 For conformity to environmental regulations and/or standards other than EU, contact
your local Yokogawa office (PIM 113-01Z2).
Typical Characteristics
Measured Current Values and Current Consumption (Typical)
-600
-500
-400
-300
-200
-100
0
100
200
300
400
500
600
-50
-40 -30 -20 -10 0 10 20 30 40 50
701928
Positive power, DC input
Negative power, DC input
Positive power, AC (50 Hz) input
Negative power, AC (50 Hz) input
Measured current (A)
)
A
m (
n o i
t p
m u
s n
o c
t n
e r r
u
C
-600
-500
-400
-300
-200
-100
0
100
200
300
400
500
600
-50
-40 -30 -20 -10 0 10 20 30 40 50
701929
Positive power, DC input
Negative power, DC input
Positive power, AC (50 Hz) input
Negative power, AC (50 Hz) input
Measured current (A)
)
A
m (
n o i
t p
m u
s n
o c
t n
e r r
u
C