Yokis MTR500 Series Manual Download Page 6

The MTT500 timed relay is equivalent to the MTM500 staircase lights timer described 

above. The only difference is that pressing the pushbutton again while the light is on will switch the light off instead of extending

the on time.

MTT500    TIMED RELAY    

MTV500    DIMMER 

MTVT500  TIMED DIMMER 

MTR500    ELECTRONIC TOGGLE RELAY 

On-off: 

A short press will switch the light on and off.

Installation              Model               Code

Flush-mounted    MTR500E      5454050

DIN rail                MTR500M     5454060

MTM500    STAIRCASE LIGHTS TIMER 

The MTM500 staircase lights timer is used to time the staircase lights.

Operation:

Press the pushbutton on the landing shortly to switch the light on for a programmed time (default: 2 minutes). Press

the pushbutton again will extend the on time.

Time configuration:

All configurations are stored in case of blackout. The default on time is 2 minutes. The time can be configu-

red from 2 seconds to 4 hours by means of short press sequences (see below). Press

25

times to set the time in seconds (from

2 seconds to 4 minutes): (reply: 5 flashes). Press shortly

26

times to go back to a timing in minutes from 2 minutes to 4 hours):

(reply: 6 blinks). 

extended time:

This function is useful for keeping the light while the staircases is being cleaned. Hold one of the connected

pushbuttons pressed for longer than 3 seconds to switch the light on for one hour (the light will flash briefly to indicate that the

control was recognised and that the on-time was set to one hour). The module will start working normally when the hour expires.

Hold the pushbutton pressed for longer than 3 seconds again to switch off before the hour. To disable (or re-enable) the ‘exten-

ded time’ function:

2

9 short presses (reply: 9 flashes). 

Warning

: The light will flash briefly one minute before the switch-on thus expires (30 seconds if the time was programmed in

seconds) and then will start gradually dimming. The pushbutton can be pressed again before the light goes out completely to

extend the switch-on time. Press shortly

24

times to deactivate (or reactivate) the warning function (reply: 4 flashes).

Configuration lock:

The module can be locked by means of a 

21

presses sequence to deactivate the possibility of changing

configurations (reply: 1 flash). The module can be unlocked at any time by means of a 

23

press sequence (reply: 3 flashes).

Installation              Model               Code

Flush-mounted    MTM500E      5454051

DIN rail                MTM500M      5454061

Module configuration table

Presses *         

Time

            Reply 

     11          2 minutes                     1 flash

     12          4 minutes                     2 flash

     13          8 minutes                     3 flash

     14          15 minutes                   4 flash

     15          30 minutes                   5 flash

     16          60 minutes (1 hour)       6 flash

     17          120 minutes (2 hours)    7 flash

     18          240 minutes (4 hours)    8 flash

     19          unlimited                      9 flash

Presses *            

Time

                      Reply 

    21                  Configuration lock                    1 flash

    22                  -                                                

    23                  Configuration unlock                3 flash

    24                  ON/OFF warning                      4 flash

    25                  Time in seconds                      5 flash

    26                  Time in minutes                       6 flash

    27                  Low light level setting              7 flash

    28                  Reset minimum brightness 

                           level (default)                           8 flash

*

SHORT PRESSES 

on the pushbutton (max. 0.8 second intervals)

The time is normally set in minutes (default) but may be

set in seconds by means of a 25 presses sequence

(reply: 5 flashes). Press shortly 26 times to return to

minutes (replay: 6 flashes).

Example: To set a 15 second time: 

1 - Press shortly 25 times to select time in seconds

(reply: 5 flashes).

2 - Press shortly 14 times to select a time of 15 in

seconds (reply: 4 flashes)

The MTVT500 timed dimmer is a dimmer (like MTV500) which integrates timer functions.

On-off:

press once shortly to switch the light on and off at the previously stored dimmer value. 

Soft start and stop functions are provided to increase the lifespan of the light bulbs. Press twice to set to 100% brightness. 

Press sequences may be used to other brightness levels (see table). 

Dimming:

Hold the pushbutton pressed (with the light on) to dim it and store the setting. The brightness is

stored when the pushbutton is released. Press again to reverse the dimming (up-down or down-up).

Low light:

With the light off, hold the pushbutton pressed to set low light (which value can be adjusted as

explained below).

Memory:

Hold the pushbutton pressed and release it to store the desired brightness level. This level will

then be recalled when the light is turned on again by means of a brief touch.

100% light:

Press the pushbutton twice to restore 100% brightness.

Memory mode or 100% light following brief touch:

100% brightness at the first touch may be required

in some applications. Press twice in this case to recall the memory. Use a 

24

short presses sequence to

activate or deactivate this mode. The module is configured in memory mode by default.

Low light level setting:

- Adjust the desired minimum level by holding the pushbutton pressed.  

- Then press shortly 

27

times: the module will flash 7 times to confirm.

- Press shortly 

28

times to restore the default minimum brightness level: the module will flash 8 times to confirm.

Configuration lock:

Press shortly

21

times to lock configurations (reply: 1 flash).

Configurations can be unlocked at any time by means of a 

23

short presses sequence (reply: 3 flashes). 

Timing (MTVT500):

The device can be set from 2 seconds to 4 hours by means of short press sequences (see table).

Press 

25

times to set the time in seconds (from 2 seconds to 4 minutes): (reply: 5 flashes).

Briefly press 

26

times to go back to a timing in minutes from 2 minutes to 4 hours): (reply: 6 flashes).

Timing is factory preset to 2 minutes; during the next minute lighting lowers until it lights out completely.

Preset dimmer settings

Memory     

1 touch

100%        

2 touches

60%          

3 touches 

40%          

4 touches

25%          

5 touches 

10%          

6 touches

Installation              Model               Code

Flush-mounted    MTT500E      5454054

DIN rail                MTT500M      5454064

DS1054-001F

Installation              Model               Code

Flush-mounted    MTV500E      5454052

DIN rail                MTV500M     5454062

Flush-mounted    MTVT500E    5454055

DIN rail                MTVT500M   5454065

P6

Summary of Contents for MTR500 Series

Page 1: ...ne utilisation pleine puissance Le micromodule doit tre uniquement install par une personne form e et dans un lieu inaccessible l utilisa teur final conform ment aux r gles d installation nationales N...

Page 2: ...flashs 28 Seuil bas au mini 8 flashs APPUIS COURTS successifs sur le BP 0 8 sec maxi d intervalle Toutes les dur es r gl es en minutes peuvent tre trans form es en secondes par 25 appuis courts r pons...

Page 3: ...finale in conformit alle norme nazionali di installazione Al fine di rispettare le normative di sicurezza il modulo deve essere connesso ad una linea elettrica protetta a monte da un interruttore magn...

Page 4: ...7 lampeggi 28 ripristino livello minimo luminosit come da fabbrica 8 lampeggi PRESSIONI RAPIDE successive sul pulsante 0 8 secondi di intervallo max La durata normalmente impostata in minuti default p...

Page 5: ...s according to the installing national rules In order to follow the safety rules the module must be connected to a power line that is upstream protected by a magne tothermic switch 10A C curve Wiring...

Page 6: ...flash 26 Time in minutes 6 flash 27 Low light level setting 7 flash 28 Reset minimum brightness level default 8 flash SHORT PRESSES on the pushbutton max 0 8 second intervals The time is normally set...

Page 7: ...nal calificado y en un lugar inaccesible para el usuario final conforme a ley nacional Para cumplir con las normas de seguridad el m dulo debe conectarse a una red protegida de aguas por un disyuntor...

Page 8: ...inosidad 7 parpadeos 28 Restablecimiento del nivel m nimo de luminosidad de f brica 8 parpadeos Secuencia de PULSACIONES R PIDAS en el pulsador 0 8 segundos de inter valo m ximo La duraci n normalment...

Page 9: ...lossen werden die vorge lagert durch einen 10A Leitungsschutzschalter mit C Kurve gesch tzt ist Verkabelung Das Modul wird in der Schaltung in Serie verkabelt Es kann beliebig sowohl auf Phase als auc...

Page 10: ...n zu unterbinden kann das Modul durch 21 Mal schnelles Dr cken gesperrt werden Antwort 1 maliges Blinken Die Sperre kann durch 23 maliges Dr cken Antwort 3 maliges Blinken jederzeit aufgehoben werden...

Page 11: ...n voor de eindgebruiker overeenkomstig de nationale installatienormen Om aan de veiligheidsnormen te voldoen moet de module worden aangesloten op een beveiligde elektriciteitsleiding na een veiligheid...

Page 12: ...mum lichtsterkte herstellen knippert 8 keer AANTAL KEER snel knop indrukken maximum 0 8 seconden tussen elke druk op de knop U schakelt de tijd die altijd ingesteld is op minuten default over naar sec...

Page 13: ...gemeinsamen Leiter der Taster auf Nullleiter NL Bedrading in de kast met de gemeenschappelijke knoppengeleder op de nulader FR Consultez plus de sch mas et renseignements techniques sur notre site In...

Page 14: ...bianco white wire hilo blanco wei er Leiter witte draad V fil violet filo viola purple wire hilo violeta violetter Leiter paarse draad O fil orange filo arancio orange wire hilo naranja orangefarbene...

Reviews: