Linhai Yida Electronics Co., Ltd
2
Ⅳ
.Trouble Shooting
Items symptoms
causes
solutions
1
Meter: no display, light off
Check the power cable
connection
Connect the power cable well and correct
2
Light on but meter no
display
check 12v and WORK
indication and transmitter
First check 12v on rudder meter, second,
check
transmitter
connection,
if
Work
indication flashes, the rudder meter is broken.
3
Too big or small angle
between left and right
rod
Adjust the rod
4
0°not correct
Check
0°
of transmitter
Correctly adjust the
0°of rudder blade and
transmitter
Ⅴ.
Installment Dimension