Technical data: 

 

- 150A is the maximum full power current  about 30 Sec.

 

- 4 to 12s LiPo, with under voltage protection by power reduction.

 

- Disconnectable under voltage detection.

 

- Optocoupler. Receiver Battery can be used up to 9V.

 

- prgrammable Soft start.

 

- The partial load capability is in line with the requirements for Hotliners. (100A about 5 sec.) 
- Automatic or 6 step adjustable timing.

 

- 3 steps adjustable regular back EMF brake.

 (smooth 0.5 s | middle 0.3s | hard 0.2s)

 

- Switching rate: 8 to 16 kHz

 

- Speed limit: 240,000 RPM (2-Pole motors)

 

- Temperature and overload warning. 
- Anti sparkling circuit, decreases the power on spark. 
- Overall dimensions in mm: 74 x 32 x 18 
- Weight in g without/with wires: 63 / 89 
- Cable diameter Battery/Motor: 4² / 4² 
- Programming with the ProgCard II or III 
 
 

 
 
 
Initial setup: 

 

After  connecting  the  battery  (red  =  plus,  black  =  minus)  you 
hear  3  descending  tones.  When  connecting  4s    to  6s  Lipo 
follows  a  number  of beeps  according  to  the number  of  cells. 
With  high  cell  packs  (7  to  12s  Lipo)  follow  2  high  and  2 
deeper  tones.  In  case  the  transmitter  stick  is  in  throttle  off, 
you hear now 3 ascending tones. 
You need to connect the motor to hear the beeps, as it is the 
motor itself which acts as a speaker. 

 

If the motor turns in the wrong direction, exchange simply 2 of 
the 3 motor wires. 

 

Use  only  clean  and  tight  gold  connectors  for  motor  and 
battery. The 5.5mm / 6mm PK connectors have proven to be 
the  best  choice.  Pay  attention  for  the  battery  connector  to 
choose  a  polarity  safe  system.  Exchange  low-friction  or 
oxidized  plugs  and  sockets.  Because  only  tight  sitting 
contacts  will  ensure  a  high  current  flow,  protect  the  speed 
controller  against  dangerous  voltage  peaks  and  avoid 
disturbances.  
 
The entire wire length, from the controller to the battery, may 
not exceed 20cm. If longer wires are necessary, a Low ESR

 

switching  capacitor  of  330µF/50V  should  be  soldered 
between  plus  and  minus  wires  every  20cm.  You  might  also 
consider  using  our  capacitor  module  YGE  Cap´s  typ  7. 
Likewise the motor wires can be extended. Then please twist 
the 3 lines, in order to minimize interference emission. 

 

 
 
Note:  Inverting  the  Battery  polarity  leads  to  heavy 
damage and to the loss of warranty!!! 
 
General Settings:

 

 
The speed controller has a fixed throttle curve setting, so that 
with  all  usual  transmitters  the  stop  and  full  power  points  are 
linearly connected. With all programmable transmitters, the  
 
 
 

 
 
 
 
throttle range should be set to default (±100%), the center 
point set to zero and throttle trim enabled. Nevertheless, 
with  
some  transmitter  types  the  range  needs  to  be  adjusted.  
For that the throttle endpoints have to be set so that one 
notch  before  lowest  stick  position  the  motor  is  stopped 
and that one notch before full power the motor is actually 
at  full  power.  Full  power  is  indicated  by  the  LED  that  is 
completely turned off. 

 

On  delivery  the  Timing  is  adjusted  to  18°,  brake  is 
switched  on  middle,  and  the  under  voltage  recognition 
adjusted to Lipo mode 3.1 V. 
 
If during spin up rpm variations (wowing or erratic sound) 
are  experienced,  the  timing  must  be  increased.  If  no 
improvement  can  be  obtained  at  30°,  then  the  motor  is 
overloaded.  Here  a  smaller  propeller,  a  one  cell  smaller 
battery  or  a  stronger  motor  will  help.  If  after  motor  stop 
you  hear  2  beeps  repeating,  it  means  that  the  battery 
voltage dropped down below the setting value. Eventually 
try  a  cutoff  voltage  of  2.9V  per  cell.  If  there  is  still  no 
improvement, then the battery is discharged or too weak, 
the wires are too long or to small or a connector is out of 
order. 
With  an  active  brake  you  can  hear  these  warning  tones 
only  in  windmill  position.  This  is  the  small  range  on  the 
throttle  stick  between  brake  and  motor  start.  You  can 
reach this position with 2 notches or with a high trim and 
a short gas start. 
 
If  no  automatic  timing  is  wished,  it  can  be  adjusted 
according to the following guideline.  
 
Innrunner 

0 to 12°  

Outrunner 

18 to 30°  

 
If 

your 

motor 

manufacturer 

indicates 

timing 

recommendation, it is of course preferable to use it. 
Basic rule: the higher the timing the higher the full power 
rpm. 
 