yellow jacket RecoverXLT2-AP Operation And Maintenance Manual Download Page 1

 

 

RecoverXLT2-AP

 Oil-Less Universal 

Refrigerant Recovery System 

Operation and Maintenance           

Manual 

 

(English) 

Summary of Contents for RecoverXLT2-AP

Page 1: ...RecoverXLT2 AP Oil Less Universal Refrigerant Recovery System Operation and Maintenance Manual English...

Page 2: ...imum use the RecoverXLT2 AP only in areas with sufficient ventilation 8 Recovery should always be performed in well ventilated areas Use the RecoverXLT2 AP only in locations where mechanical ventilati...

Page 3: ...t out of the system and transfer it into a recovery cylinder Liquid recovery is accomplished by connecting to the high pressure system discharge service port liquid port side of the system being servi...

Page 4: ...and discharge ports of recovery machine For best performance use 3 8 hoses 6 Purge all hoses of non condensables before recovering refrigerant into recovery cylinder 7 Open the liquid valve on the rec...

Page 5: ...akes the reconfiguration to vapor recovery easier and faster to do Some HVAC systems will not allow for the push pull recovery method If any of the following conditions apply do not use push pull meth...

Page 6: ...ipment should not be used with this refrigerant Take time to read the safety instructions that came with the device you are servicing as well as any material that came with your refrigerant WARNING US...

Page 7: ...frigerant will be recovered The first job of the day usually means a fresh empty tank and no cause for worry about over filling However the last job of the day means there is already liquid in the tan...

Page 8: ...er clogged Clean or replace suction filter Selector valve in wrong position Put selector valve in liquid or vapor recovery position Unit will not pull a vacuum Hoses are not tight Tighten hoses Leak i...

Page 9: ...3 7 205 152 R 134a 0 20 4 20 3 14 12 252 188 R 404A 0 30 3 66 2 73 18 220 164 R 410A 0 18 3 70 2 77 11 222 166 R 1234yf 0 17 3 83 2 86 10 230 171 R 407C 0 18 3 99 2 98 11 240 179 Compressor 1 2 HP Rec...

Page 10: ...reason able costs YELLOW JACKET Products Division Ritchie Engineering Co Inc 10950 Hampshire Avenue South Bloomington MN 55438 e mail custserv yellowjacket com Web Site www yellowjacket com Phone 800...