Administrator’s Guide for W80 DECT IP Multi-Cell System
103
Example: Keeping User’s Personalized Settings
This section shows you how to keep the personalized settings.
Parameters Settings:
static.auto_provision.custom.protect =1
After provisioning, if the users make changes via the phone user interface or web user interface, the MAC-local.cfg
file with non-static personal settings generates locally.
Scenario: Keeping user’s personalized settings when upgrading the firmware
If you set “
static.auto_provision.custom.sync =1”, then the phones attempt to upload the MAC-local.cfg file to the pro-
visioning server each time the file updates. When performing auto provisioning, they download their own MAC-loc-
al.cfg file from the provisioning server, and then update settings in MAC-local.cfg file to the IP phone system. The
personalized settings locally are overridden by the MAC-local.cfg file from the provisioning server.
If you set “
static.auto_provision.custom.sync =0”, the MAC-local.cfg file will be kept locally. The personalized set-
tings will not be overridden after auto provisioning.
Scenario: Keeping user personalized settings after factory reset
The IP phone requires a factory reset when it has a breakdown, but the user wishes to keep personalized settings
of the phone after a factory reset. Before factory reset, make sure that you have set “
static.auto_pro-
vision.custom.sync =1”, and the MAC-local.cfg file has kept on the provisioning server.
After resetting all configurations to factory defaults, both the parameters settings “
static.auto_pro-
vision.custom.protect” and “static.auto_provision.custom.sync” are reset to 0. Although the MAC-local.cfg files loc-
ally are cleared, they are still kept on the provisioning server.
You can set “
static.auto_provision.custom.protect =1” and “static.auto_provision.custom.sync =1”, and then trigger
the phone to perform auto provisioning. The phones download their own MAC-local.cfg file from the provisioning
server, and then update settings in MAC-local.cfg file to the IP phone system.
As a result, the personalized configuration settings of the phone are retrieved after the factory reset.
Clearing User's Personalized Configuration Settings
When the IP phone is given to a new user but many personalized configurations settings of the last user are saved
on the phone; or when the end-user encounters some problems because of the wrong configurations, you can clear
the user’s personalized configuration settings via the web user interface at the path:
Settings
>
Upgrade
>
Reset
Local Settings
.
Note
: The
Reset local settings
option on the web user interface appears only if you set “static.auto_pro-
vision.custom.protect = 1”.
If you set “static.auto_provision.custom.sync = 1”, the MAC-local.cfg file on the provisioning server will be cleared too. If not,
the MAC-local.cfg file is kept on the provisioning server, and the phone could download it and update the configurations to the
phone after the next auto provisioning.
Custom Handset Related Configurations
This section shows you the custom handset related configurations.
Parameter
Related Topic
custom.handset.date_format
Time and Date Format Configuration
custom.handset.time_format
custom.handset.auto_answer.enable