background image

Installation and Operation Guide SOLECTRIA XGI 1000  
 

DOCR-070733-F (2/22/2021) 

 

Page 14 of 78 

 

Mounting Bracket Assembly  1 

Mounting Bracket assembly, 3 pieces 

M5 x 0.8, Nut 

Mouthing Bracket nut, M5x0.8 SS Nut 

Shield 

Front shield, between Power Head and Wire Box 

Antenna Adapter, WIFI 

WIFI antenna for GUI 

Antenna, WIFI 

90° coaxial WIFI antenna adapter, male to female 

2-Position Jumper 

2 position jumper, neutral to ground bonding 

M5 x 0.8, Nut 

Inverter Box to Wiring Box, M5x0.8, SS nut 

M5 x 0.8, Screw 

Inverter Box to Wiring Box, M5x0.8, 16mm long, SS screw 

M5 x 0.8, Screw 

Front shield, M5x0.8, 12mm long, SS screw 

M6 x 1.0, Screw 

Mounting Bracket, Wire Box, M6x1.0, 12mm Long, SS screw 

Table 2-3 Contents of Boxes 

 

 

 

Summary of Contents for XGI 1000-65/65

Page 1: ...Commercial 1000VDC String Inverter SOLECTRIA XGI 1000 Installation and Operation Guide Models XGI 1000 65 65 XGI 1000 60 65 XGI 1000 60 60 ...

Page 2: ...rams 11 Labels 12 Unpacking 13 Installation 15 Installation Sequence Overview 15 Mechanical Installation 16 Electrical Installation AC 27 Electrical Installation DC 34 Communication Installation 41 Communication and I O Ports XGI 1000 Only 49 Resealing the Wiring Box 50 Startup 52 Startup Steps for a Single Inverter 52 Graphical User Interface 54 XGI Terminology 54 Graphical User Interface GUI Ove...

Page 3: ...ubleshooting 64 Event Codes 64 Servicing the Fans 69 WiFi Connection Error 70 Specifications 71 General Specifications 71 Voltage and Frequency Limits and Trip Times 72 Temperature and Altitude 74 Enclosure 75 Options 76 Wiring Box Configurations 76 Appendix 78 Warranty and RMA Instructions 78 Datasheet 78 Contact Information 78 ...

Page 4: ...t in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a hazardous condition which if not avoided could result in property damage INFO Indicates important supplementary information to use the product effect...

Page 5: ... F 2 22 2021 Page 5 of 78 Symbols on Labels Table 1 1 Explanation of Symbols on Labels SYMBOL DESCRIPTION DC Signal AC Signal Equipment Ground Phase Off On Refer to Operating Instructions Caution Risk of Electric Shock Caution Risk of Electric Shock Timed Discharge ...

Page 6: ...ll local national and country specific guidelines for safety Electrical Shock Hazard Operator may contact components with hazardous voltage and energy Use proper safety equipment including Personal Protective Equipment PPE when de energizing the unit De energize the unit wait 5 minutes and verify the absence of voltage before opening the equipment or removing any protective shields NOTICE General ...

Page 7: ...llation and Operation Guide SOLECTRIA XGI 1000 DOCR 070733 F 2 22 2021 Page 7 of 78 SAVE THESE INSTRUCTIONS This manual contains important instructions for models XGI 1000 65 65 XGI 1000 60 65 XGI 1000 60 60 ...

Page 8: ...n Status Panel SYMBOL DESCRIPTION Ready Yellow On Inverter is initialized and ready to operate Off Inverter is not ready to operate Network and Communication Yellow On Network and communication services are working properly Off Network and communication services are offline Power Yellow On Inverter is generating AC power Off Inverter is not generating AC power Maintenance Yellow On Inverter requir...

Page 9: ...0 converts solar power DC to 480VAC power suitable for use in buildings and back feeding onto the electrical grid The SOLECTRIA XGI 1000 is an ideal product for use in rooftop carport or ground mount installations where quality and performance are paramount The SOLECTRIA XGI 1000 is not intended for use in micro grid or off grid applications Although successful integration into AC couple systems i...

Page 10: ...t aluminum Rated for indoor and outdoor use EASY INTEGRATION Integrated AC and DC switches 16 fused input positions Accommodates wide range of AC DC conductors Compatible with approved external combiner boxes Inverter Protections DC POLARITY Reverse polarity protection on DC inputs SHORT CIRCUIT PROTECTION ARC FAULT DC series arc fault detection ANTI ISLANDING Slip mode anti islanding detection OV...

Page 11: ...point of access to all inverters within a network without needing to travel the site to interact with individual inverters The SOLECTRIA XGI 1000 is compatible with Solectria s SolrenView with no additional hardware required Yaskawa Solectria also supports integration with other third party monitoring platforms For a complete list of compatible monitoring visit www solectria com Figure 2 2 Communi...

Page 12: ... XGI 1000 60 60 Left and SOLECTRIA XGI 1000 65 65 Right The label on the Wiring Box shows the Model the order code C C the Enclosure Type and Serial Number Figure 2 5 Figure 2 5 Example Label for XGI 1000 Wiring Box The Model code contains important information about the Wiring Box configuration see Table 2 1 for the Model code Matrix Table 2 1 Model Matrix MODEL EXAMPLE WB 1000 16X15A L IND MODEL...

Page 13: ...Never expose packaged inverters to rain water snow or other elements that may damage the electronics The Power Head and Wiring Box are not NEMA Type 4X rated until fully installed Failure to store the inverters properly will result in property damage that is not covered under warranty INFO Do Not Discard Packaging Before Removing all Contents There are multiple components in each box check packagi...

Page 14: ... F Antenna Adapter WIFI 1 WIFI antenna for GUI G Antenna WIFI 1 90 coaxial WIFI antenna adapter male to female H 2 Position Jumper 1 2 position jumper neutral to ground bonding I M5 x 0 8 Nut 4 Inverter Box to Wiring Box M5x0 8 SS nut J M5 x 0 8 Screw 4 Inverter Box to Wiring Box M5x0 8 16mm long SS screw K M5 x 0 8 Screw 2 Front shield M5x0 8 12mm long SS screw L M6 x 1 0 Screw 2 Mounting Bracket...

Page 15: ...l requirements and guidelines which must be considered when designing a system and planning the installation Each sub section is concluded with detailed systematic instructions to install the SOLECTRIA XGI 1000TM Installation Sequence Overview 1 Assemble and install the Mounting Bracket 2 Install the Wiring Box to the bottom portion of the mounting bracket CAUTION Lifting Heavy Object Hazard Prope...

Page 16: ...nged snow coverage or near explosive or flammable materials WARNING Exposion or Fire Hazard Electrical devices can cause fires Never install in areas prone to explosive gasses liquids or in close proximity to flammable materials NOTICE Installation Must Maintain NEMA Type 4X Rating It is the responsibility of the installer to maintain the NEMA Type 4X rating of the enclosure Failure to maintain th...

Page 17: ...talled vertically When possible install inverters under cover or in a north facing orientation The inverter Power Head must be installed above the inverter Wire Box never install the inverter upside down The bottom edge of Wiring Box must remain horizontal perpendicular to a plumb line no side to side tilting is permitted Figure 3 2 Inverter Mounted INCORRECTLY with Power Head below the Wiring Box...

Page 18: ... F 2 22 2021 Page 18 of 78 Inverter Dimensions The dimensions of the SOLECTRIA XGI 1000TM are shown in Figure 3 3 For a more detailed drawing visit www solectria com to download the Customer Interface Drawing available as a pdf or dwg Figure 3 3 Inverter Dimensions ...

Page 19: ...th a dashed line free from debris plants and other obstructions NOTICE Improper Installation Will Void Warranty The requirements defined in this section are the minimum allowable clearances In areas that experience deep snows heavy rain excessive heat or excessive vegetation growth it may be necessary to increase spacing It is the responsibility of the installer to ensure the clearance area remain...

Page 20: ...proper Installation Will Void Warranty Always use the provided mounting bracket secured to a structurally sound surface Never modify the inverter Power Head or Wiring Box enclosure doing so will void the warranty CAUTION Improper Installation may result in Property Damage or Personal Injury Never install the inverter directly to drywall unless attached to a structural member Installing the inverte...

Page 21: ...Installation and Operation Guide SOLECTRIA XGI 1000 DOCR 070733 F 2 22 2021 Page 21 of 78 Figure 3 5 Mounting Bracket mounting holes 1 2 3 4 ...

Page 22: ...racket The Mounting Bracket assembly includes three 3 pieces of sheet metal A B C and four 4 M5 x 0 8 SS nuts D as shown in Figure 3 6 Align the holes of sheet metal B with the studs on sheet metal A and C as shown in Figure 3 7 Use four 4 M5 x 0 8 SS D nuts to fasten the three pieces together Using an 8mm socket torque to 20 in lbs 2 3 N m Install the assembled Mounting Bracket on the desired sur...

Page 23: ...Installation and Operation Guide SOLECTRIA XGI 1000 DOCR 070733 F 2 22 2021 Page 23 of 78 Figure 3 7 Bracket Assembly D F D F F F ...

Page 24: ...Box onto the Mounting Bracket and align the PEMs on the Wire Box with the clearance holes on the Mounting Bracket as shown in Figure 3 8 Use two 2 M6 x 1 0 12mm screws to secure it in place torque the screws to 40 in lbs 4 5 N m using a 10mm socket Figure 3 8 M6 Connecting Bolt Right Side Shown Install one 1 M6 x 1 0 12mm screw in the bottom of the Wire Box for the external auxiliary equipment gro...

Page 25: ...nections in the blind mate connector Installing the Power Head in a misaligned position or with too much force may damage the equipment permanently Damage caused by improper installation is not covered under warranty Using a two man lift position the Power Head on top of the Wire Box Align the Power Head and Wire Box using the metal bracket and guide pins The Power Head should slide into position ...

Page 26: ...a Attach the antenna to the 90 coaxial antenna adapter do not over tighten Connect the antenna assembly to the inverter Power Head ensure that the antenna remains vertical regardless of the inverter mounting angle INFO Antenna Orientation the WIFI antenna must remain vertical regardless of the installation angle Figure 3 11 Assemble and Install Antenna ...

Page 27: ...ted for 480 VAC 60Hz 3 Phase grounded Wye Installing the inverter on any other electrical grid will damage the inverter and void the warranty INFO Grid Mismatch If the grid does not match the requirements of the inverter the inverter will not start Check with your local electric utility before selecting a grid profile The system must comply with National Electrical Code ANSI NFPA 70 and with all l...

Page 28: ...erly this connection will not affect the function of the inverter Always check with the AHJ before removing the neutral conductor and installing the neutral to ground jumper NOTICE Neutral to Ground Jumper Do not use a jumper between neutral and ground if the neutral conductor is connected Using a jumper with then neutral conductor connected may result in damage and void the warranty AC Conductor ...

Page 29: ...I 1000 60 60 XGI 1000 60 65 XGI 1000 65 65 AC BREAKER SIZE 100 A 3 pole 100 A 3 pole 100 A 3 pole 100 A 3 pole Use of Aluminum Conductors The AC terminals in the SOLECTRIA XGI 1000TM are dual rated by UL for use with copper or aluminum conductors When using aluminum conductors it is important to prepare the conductors properly to prevent oxidation and overheating Follow the steps below to prepare ...

Page 30: ...duit Installation All conduit connections must be made in such a way as to maintain the NEMA Type 4 rateing of the enclosure Failure to maintain the NEMA rating will void the warranty Table 3 4 Electrical Installation AC Tools Required TOOL DESCRIPTION SLOTTED SCREW DRIVER 3 16 or 4 75mm slotted screw driver 3 PHILLIPS HEAD TORQUE DRIVER 3 Phillips head torque driver capable of 30 in lbs 2 PHILLIP...

Page 31: ...OLECTRIA XGI 1000 DOCR 070733 F 2 22 2021 Page 31 of 78 Remove Wire Box Cover Use a 3 Phillips head screwdriver to remove the ten 10 screws from the cover of the Wire Box as shown in Figure 3 15 Figure 3 15 Remove Wire Box Cover Screws ...

Page 32: ...ior to landing any conductors Turn the external AC breaker OFF Verify the absence of AC voltage prior to landing any conductors Land the ECG in the left most terminal block see Figure 3 17 Using a 4 75mm flat head screw driver torque to the proper value reference Table 3 5 If required land the neutral conductor in the terminal block see Figure 3 17 Using a 4 75mm flat head screwdriver torque to th...

Page 33: ...m running If the inverter reports a PLL Phase Lock Loop error or the frequency voltage measurements seem incorrect check your phase rotation Swapping any two AC conductors will reverse the phase rotation Table 3 5 AC Torque Specification PHASE WIRES GROUND NEUTRAL STANDARD WIRING BOX 25 in lbs 2 8 N m 25 in lbs 2 8 N m 25 in lbs 2 8 N m LARGE AC TERMINAL L WIRING BOX 80 in lbs 9 0 N m 25 in lbs 2 ...

Page 34: ...de of the wiring box all negative conductors must be landed on the right side fuse holders Both positive and negative conductors are fused See Figure 3 14 for a detailed layout of the wiring compartment The SOLECTRIA XGI 1000TM is available in configurations with all zones MPP tracking independently Independent Mode or in parallel Combined Mode Independent Mode provides design flexibility when dea...

Page 35: ...configured Combined Mode installations perform the calculations based on the total inverter nameplate power rating With a maximum DC to AC ratio of 1 5 at STC conditions Equation 3 1 a user can connect up to 90 kW XGI 1000 60 60 XGI 1000 60 65 and 97 5 kW XGI 1000 65 65 NOTICE High Irradiance Installations In applications that may experience higher than 1000 W m2 on a regular basis it is recommend...

Page 36: ...ned Mode When ordering select the Wire Box model with the desired operating mode Independent Mode or Combined Mode WARNING Unequal String Lengths and Module Mismatch Unequal string lengths and significant module mismatch can result in the flow of current between strings connected in parallel Opening fuses under load can cause a hazardous condition It is strongly recommended to avoid unequal string...

Page 37: ...00 850 VDC OPERATING VOLTAGE RANGE MPPT 350 950 VDC 350 950 VDC 350 950 VDC MAXIMUM OPERATING INPUT CURRENT 105 6 A 26 4 A per zone 105 6 A 26 4 A per zone 110 6 A 27 65 A per zone MAXIMUM OPERATING PV POWER PER MPPT ZONE 15 3 kW 15 3 kW 16 6 kW MAXIMUM RATED PV INPUT PER MPPT ZONE 22 5 kW 22 5 kW 24 4 kW ABSOLUTE MAXIMUM INPUT VOLTAGE 1000 VDC 1000 VDC 1000 VDC NUMBER OF MPP TRACKING ZONES 4 1 4 ...

Page 38: ...ery other fuse position Never install PV inputs in two adjacent fuse holders Doing so may result in overheating and damage to the inverter and will void the warranty External Combiner Boxes The SOLECTRIA XGI 1000TM is compatible with external combiner boxes when operating in Independent Mode ONLY The external combiner box MUST have four separate zones The zone output conductors coming from the com...

Page 39: ... NOTICE Check Polarity of DC Inputs DC inputs with the wrong polarity may cause damage to the inverter Check for proper polarity with a multimeter Use Correct Fuses Make sure to size the fuses according to NEC requirements If using 30 A fuses skip every other fuse holder DO NOT place 30 A fuses in adjacent fuse holders Table 3 7 DC Electrical Installation DC Tools Required TOOL DESCRIPTION 3 PHILL...

Page 40: ...Installation and Operation Guide SOLECTRIA XGI 1000 DOCR 070733 F 2 22 2021 Page 40 of 78 Figure 3 22 DC Connections for Single Zone Fused Connection ...

Page 41: ... connection with ground INFO Ethernet Cat 6 Shielded Cable Solar PV inverters create an electrically noisy environment that can disrupt inverter communication It is important to use Cat 6 Shielded cable to ensure that communication is not interrupted Separate Communication Conductors from Power Conductors Never run communication conductors in the same conduit as power conductors It is important to...

Page 42: ... exceed 50 Use shielded Cat6 Ethernet cable ONLY The maximum length between any two devices is 328 ft 100m for all inverter Ethernet connections Fiber optic cables can be used for long haul communication runs with the use of an appropriate switch converter Ethernet Cat6 Shielded INV 50 INV 49 INV 2 INV 1 Gateway Inverter Modem or Internet Gateway Internet Firewall Figure 3 23 Ethernet daisy chain ...

Page 43: ... robust built in firewall that is automatically established on the Gateway Inverter after receiving an IP address assigned via a DHCP or through manual static IP configuration This act of establishing a firewall also designates an inverter as a Gateway Inverter Once this firewall is established unauthorized inbound or outbound communication is not permitted through the Gateway Inverter Networking ...

Page 44: ... MUST be employed in order for the third party DAS to reach each inverter as an Endpoint Device 1 Port forwarding 2 Static Routing discussed in detail in Section 3 5 7 Be sure to consult with the monitoring provider before installation Third Party Data Acquisition System DAS Connection NOTICE Ethernet Only Connection The XGI 1000 series inverter only supports Ethernet connections to a third party ...

Page 45: ...rter using the Gateway Inverter External IP and the specified port for the inverter with the cluster The Gateway Inverter External IP is assigned to the Gateway Inverter via the DHCP or configured manually using a static IP Port Forwarding Reserved DHCP IP Address Before configuring Port Forwarding on the Gateway inverters s it is important to work with your network administrator to ensure that th...

Page 46: ...an entire IP subnet will not only allow the desired DAS device but would also enable all the other devices authorized or unauthorized in the subnet to be able to access the Inverter cluster LAN Use the most restrictive settings possible Figure 3 28 Enabling external Modbus access Port Forwarding Enable Configure Rules for Port forwarding by selecting the check box Enter all of the desired Ports in...

Page 47: ... Device by a DAS or other external device using the Inverter Cluster IP address and port 502 for example 10 78 125 31 502 Inverter Cluster IPs can be configured see Section 3 5 8 Static Routing Configuring the Gateway Inverter To configure Static Routing first Enable External Modbus Access by selecting the check box using the GUI of the desired Gateway Inverter By default the Gateway Inverter will...

Page 48: ... IP on the Modbus Access Configuration page see Figure 3 29 The method of entering static routing rules varies depending on the device or operating system for more information work work with your IT professional Manage Cluster IP Address The internal Cluster IP Address are automatically assigned to each XGI inverter at the factory If desired the IP address can be managed and statically assigned Su...

Page 49: ...Communication and I O Ports XGI 1000 Only The SOLECTRIA XGI has a 16 pin I O port and two interchangeable Ethernet Ports see Figure 3 31 These connections are located in the right hand compartment within the Wire Box Figure 3 31 Communications Connections and Ports 2 Ethernet Ports Left and 16 Pin I O Port with Connector Right ...

Page 50: ...uxiliary power supply for the inverter 16 Output Source for 24 VDC 0 5 ADC for auxiliary devices Table 3 9 Connection Specifications for 16 Pin I O Connector WIRE SIZE 28 16 AWG 0 08 1 5 MM2 TORQUE 5 in lbs 0 56 N m TORQUE SCREWDRIVER SIZE 5 64 in 2 mm Weather Station Connection Optional Only use weather stations that connect using Ethernet As with all other non inverter Ethernet devices these sho...

Page 51: ... MUST be sealed with electrically rated conduit foam to restrict airflow Follow the manufactures recommendations WATER INGRESS WILL VOID WARRANTY It is the responsibility of the installer to maintain a dry moisture free inverter enclosure water ingress is not covered under warranty Install Conduit Foam All conduit entrances must be sealed conduit foam Ensure to use a product that is listed for use...

Page 52: ...re proper See DC Connections Make sure the open circuit voltage of input strings is less than 1000VDC Startup Steps for a Single Inverter WARNING Electrical Shock Hazard Installer may come into contact with components that have hazardous voltage and energy potential PPE Use proper safety equipment when energizing the inverter INFO Quick Start Guide For more details regarding communication commissi...

Page 53: ...ct the gateway node in blue at the top of the list b Log in to the inverter see Inverter Page c Select the First Time Start Wizard from the menu under Inverter Configurations d Follow the instructions of the First Time Start Wizard 7 Measure output current to verify that the inverter is operating ...

Page 54: ...a which is used to tether a smart device to the inverter or Cluster Inverters do not communicate to each other over WiFi all inter inverter communication is over Ethernet only XGI Gateway Inverter Every XGI Cluster has one and only one XGI Gateway Inverter The Gateway Inverter functions as the master to the rest of the inverters within the Cluster controlling communication with other devices outsi...

Page 55: ...XGI Inverter DHCP must be enabled on the PC connected to the inverter Once the laptop recognizes the Ethernet connection open your preferred web browser example Firefox or Chrome and type xgi solar in the address bar then click Enter to navigate to the website The laptop should establish a connection with the inverter and display the GUI INFO Having trouble connecting to the XGI over Ethernet Veri...

Page 56: ...sing your web browser and re opening a new session Check to make sure the XGI network LED is illuminated The inverter takes approximately 5 minutes to fully boot up if connecting after a recent power cycle wait 5 minutes and try again Inverter List The Inverter List is the default display shown when first logging into an XGI network cluster The Inverter List shows a register of all the inverters c...

Page 57: ...e power Inverter Warning This indicates that the inverter has an issue but can produce power In the sample inverter list in Figure 6 1 Inverter List several nodes are worth noting Inverter 2 1 This inverter indicated in bold is the inverter that the smart device or laptop last accessed and it is operating normally Inverter 2 2 This inverter is the Gateway Inverter denoted with the gateway symbol I...

Page 58: ...er Configurations options in the menu in administrator mode Everything that is accessible in observer mode is also accessible in administrator mode If the Logout button is pressed in administrator mode the user returns to observer mode Table 6 4 shows the credentials needed to login as an administrator Table 6 4 Default Login Credentials DEFAULT USER NAME CASE SENSITIVE DEFAULT PASSWORD CASE SENSI...

Page 59: ...cceptable data The Exit button can be used to escape or back up to the previous page The Home button can be used to escape or back up to the Home page Help Many of the pages within the GUI feature a Help section containing important information regarding the particular settings or functions Make sure to review the Help sections where applicable ...

Page 60: ... Fault Logs Edit Inverter List Firmware Update First Time Start Wizard AC Voltage and Frequency Trip Settings Power Limiting Power Factor Control Reactive Power Control Volt VAr Volt Watt Freq Watt Ramp Rate Settings Abnormal AC Voltage Detection Abnormal AC Freq Detection Recovery Settings Edit Inverter Name Time and Date Configuration Factory Default Edit Lifetime Energy Restart Inverter Interne...

Page 61: ...V power has stabilized but prior to peak production reducing lost revenue Having the Enable Automatic Remote Firmware update unchecked is not recommended as product improvements may have occurred since the purchase of the product If the user disables this feature the site operator will be responsible for performing any firmware updates Manual Firmware Updates Locally Manual firmware updates perfor...

Page 62: ...o the Cluster Connect to the desired Cluster over Ethernet or WiFi using a smart device If connecting over Ethernet be sure not to disrupt the daisy chain or star network always connect to an inverter at the end of a chain INFO Don t Break the Chain When connecting to a Cluster over Ethernet during the commissioning process it is important that the Cluster LAN remain intact Always connect to an op...

Page 63: ...own list Choose a Cluster Name SSID A Cluster Name or SSID consists of three parts the Site Name Cluster ID and WiFi channel The Cluster Name generated in this step will determine the WiFi SSID or WiFi network name Operation Inverter Start Up Automatic Start Up The inverter will start up automatically when the output voltage and power from the PV array meet the required values and the AC grid is w...

Page 64: ...tempt to update the firmware and power cycle the inverter Contact Technical Support 2 Internal Communication 1 Failure Internal communication failure detected Attempt to update the firmware and power cycle the inverter Contact Technical Support 3 Internal Communication 2 Failure Internal communication failure detected Attempt to update the firmware and power cycle the inverter Contact Technical Su...

Page 65: ...perational Self Check Failure Inverter self diagnostic check has failed during operation Inverter requires service Power cycle the inverter If the inverter does not clear the error contact Technical Support 12 Startup Self Check Failure Inverter self diagnostic check has failed at startup Inverter requires service Power cycle the inverter If the inverter does not clear the error contact Technical ...

Page 66: ...frequency If there is a discrepancy of greater than 2 between the measured results and the frequency reported by the inverter contact Technical Support otherwise wait for the grid conditions to improve 9 AC Low Voltage 1 Detected AC low voltage region 1 detected Using a CAT III multi meter verify the AC voltage If there is a discrepancy of greater than 2 between the measured results and the voltag...

Page 67: ... has failed Check to make sure the Ethernet connections are firmly seated Check the Wi Fi antennas ensure they are vertically mounted 29 Software Update Fault Communication processor software update fault Power cycle the inverter If the inverter does not clear the error contact Technical Support 30 Unauthorized Network Access An unauthorized attempt to access the network has occurred Check whether...

Page 68: ...erating replace fans if necessary Make sure the ambient temperature is within normal operating conditions 2 Power Derating Customer Command Inverter output power is reduced in response to user command Verify that that a request has been made to de rate the inverter If this request has not been made contact Technical Support 3 Remote Shutdown Command Remote shutdown command was issued from the GUI ...

Page 69: ...of Power Head The AC and DC fans are different parts and cannot be interchanged To access the fans remove the screw with a 2 Phillip head screwdriver and press the tabs together to remove the assembly See Figure 10 1 to remove the DC Fans and the AC Fan Figure 10 1 DC Fans Left and AC Fan Right On the top of the fans there are two arrows at a 90 angle Fan alignment is based on the arrow that point...

Page 70: ...screw to 20 in lbs 2 3 N m See Figure 10 1 to remove the DC fans ELC 100275 AC Fan Align the fan so the fan blows OUT of the inverter The arrow will be pointed out of the inverter and the label will be visible After servicing the fan replace the assembly and torque the screw to 20 in lbs 2 3 N m See Figure 10 1 to remove the AC fan ELC 100397 WiFi Connection Error When connecting to the inverter i...

Page 71: ...PERATING INPUT CURRENT PER INVERTER 105 6 A 105 6 A 110 4 A MPP TRACKERS 1 or 4 configurable 1 by default MAX OPERATING INPUT CURRENT PER MPPT ZONE 26 4 A 26 4 A 27 6 A MAX PV CURRENT ISC X 1 25 50 A per zone or 180 A combined MAX INPUT BACK FEED 0 A OUTPUT POWER FACTOR Unity 0 99 Adjustable from 0 85 to 0 85 GRID TYPE 3 Phase Wye with Ground and Neutral NOMINAL OUTPUT VOLTAGE 480 VAC NOMINAL FREQ...

Page 72: ...2 Default Voltage Limits and Trip Times VOLTAGE RANGE VOLTAGE SETPOINT CLEARING TIME V 45 V 45 0 16 s 45 V 60 V 60 1 0 s 60 V 88 V 88 2 0 s 88 V 110 N A No trip 110 V 120 V 110 1 0 s V 120 V 120 0 16 s Table 11 3 Frequency Limits and Trip Times FREQUENCY RANGE FREQUENCY SETPOINT TRIP TIME F 57 HZ F 57 Hz 0 16 s 57 HZ F 59 5 HZ F 59 5 Hz 2 0 s 59 5 HZ F 60 5 HZ N A No trip 60 5 HZ F 62 HZ F 60 5 Hz...

Page 73: ...Installation and Operation Guide SOLECTRIA XGI 1000 DOCR 070733 F 2 22 2021 Page 73 of 78 Figure 11 2 Derating with DC Voltage ...

Page 74: ... Normal Temperature Ranges XGI 1000 50 60 AND XGI 1000 60 60 XGI 1000 60 65 AND XGI 1000 65 65 AMBIENT TEMPERATURE RANGE 40 F to 140 F 40 C to 60 C DERATING TEMPERATURE 122 F 50 C 113 F 45 C STORAGE TEMPERATURE RANGE 40 F to 167 F 40 C to 75 C Figure 11 3 Derating with Temperature Figure 11 4 Derating with Altitude All Models ...

Page 75: ...ble 11 5 Enclosure Information ENCLOSURE RATING NEMA TYPE 4 DIMENSIONS 45 8 in x 28 3 in x 11 6 in 1163 x 719 x 295 mm WEIGHT Power Head 117 lbs 53 07 kg Wiring Box 49 lbs 22 22 kg Mounting Bracket 20 lbs 9 07 kg MOUNTING ANGLE RANGE 5 90 from Horizontal ENCLOSURE FINISH AND TYPE Powder Coated Aluminum ...

Page 76: ... 1 to 1 0 AWG 42 4 to 50 mm2 3 to 3 0 AWG 26 7 to 85 mm2 1 to 3 0 AWG 42 4 to 85 mm2 NEUTRAL NOT A CURRENT CARRYING CONDUCTOR CAN BE SIZED EQUAL TO OR LARGER THAN THE EGC Copper Aluminum 8 to 4 AWG 8 4 to 21 2 mm2 6 to 4 AWG 13 3 to 21 2 mm2 6 to 1 0 AWG 13 3 to 50 mm2 6 to 1 0 AWG 13 3 to 50 mm2 EQUIPMENT GROUNDING CONDUCTOR EGC Copper Aluminum 8 to 4 AWG 8 4 to 21 2 mm2 6 to 4 AWG 13 3 to 21 2 m...

Page 77: ... 77 of 78 Large AC Terminal Configuration The Large AC Terminal Wiring Box as shown in Figure 12 2 is the Standard Wiring Box with larger AC Terminals allowing for larger AC wires to be used See Table 12 1 for allowed AC conductor sizes Figure 12 2 Wiring Box with Large AC Terminal ...

Page 78: ...solectria com support documentation warranty information grid tied inverter warranty letter Datasheet https solectria com support documentation inverter datasheets xgi 1000 datasheet Contact Information Table 13 1 Contact Information TELEPHONE 978 683 9700 FAX 978 683 9702 SALES SUPPORT inverters solectria com TECHNICAL SUPPORT SERVICE 978 683 9700x2 WEBSITE www solectria com ...

Reviews: