VS-616/676 SeriesOption Instruction Manual
Isolated Analog Monitor Card AO-12B2
Page 1: ...VS 616 676 Series Option Instruction Manual Isolated Analog Monitor Card AO 12B2...
Page 2: ...to eliminate the possibility of static charge if present affecting the card Failure to observe this precaution may result in equipment damage NOTICE Printed April 1998 The information contained within...
Page 3: ...t from each other The Isolated Analog Monitor Card can be used on any of the following inverters When inquiring with the factory please refer to the specific inverter s model and code number When used...
Page 4: ...digital operator a For smaller inverters push inward on the cover at the indented area located near the bot tom on each side of the cover While lifting the cover pivot the cover s bottom upward b Lar...
Page 5: ...olated Analog Monitor Card AO 12B2 Note VR1 VR2 VR3 and VR4 are factory calibrated and should not be readjusted Monitor Card Code Number Locations Fig 2 Underside of Card 1 2 3 VR1 HDR2 HDR1 TB1 HDR3...
Page 6: ...6VG3 VS 676VH3 3CN TB1 2 TB1 3 10k 10k OV Isolated Analog Monitor Card AO 12B2 FM AM Fig 3 Interconnection Between Inverter and Peripheral Equipment Fig 3 shows interconnection of the inverter with th...
Page 7: ...at the inverter side only to terminal TB1 3 C WRAP insulating tape around exposed shielded sheathed areas and wires where termination occurs 3 Care must be taken in the selection of the twisted shield...
Page 8: ...listed in the following table Stripping TB1 Signal Wires for Connection The following shows the correct length of insulation to be stripped in order to connect the wire to the Ter minal Blocks TB1 Cab...
Page 9: ...annel One Jumper Selections Signal Level HDR4 Jumper Positions HDR2 Jumper Positions Voltage 10 to 10 Current 0 20mA 4 20mA 1 2 3 VR1 HDR2 HDR1 TB1 HDR3 HDR4 VR4 VR3 VR2 Header Pin Layout 1 3 5 2 4 6...
Page 10: ...utput signal level varies 0 to 10 volts In this case negative polarity 0 to 10 cannot be output Output signal level can be adjusted to a maximum of 10 volts by setting program constants Table 5 Channe...
Page 11: ...1 Channel 1 Sn 28 1st 2nd digit 00 Output frequency Max frequency 100 1 0 01 Output current Inverter rated voltage 100 3 0 TB1 2 Channel 2 Sn 28 1st 2nd digit 10 Output voltage reference Input voltag...
Page 12: ...bn 15 1 Frequency reference Max frequency 100 1 0 2 Output frequency Max frequency 100 3 0 3 Output current Rated current 100 1 5 4 Output voltage reference input voltage 100 1 5 5 DC voltage VPN 400v...
Page 13: ...acity kW 5 09 Torque reference internal 10V motor rated torque 5 15 Terminal 13 input voltage 10V 10V or 20ma 0 2 16 Terminal 14 input voltage 10V 10V or 20mA 0 2 TB1 2 Channel 2 F4 03 17 Terminal 16...
Page 14: ...400V 100 200V class 800V 100 400V class 21 Speed reference SFS input Max rotation speed 100 1 0 22 Speed reference SFS output Max rotation speed 100 TB1 2 Channel 2 bn 17 23 Speed feedback Max rotati...
Page 15: ...to 2 50 0 01 1 00 TB1 2 F4 04 0 50 Programming Example Program a G5 inverter to output a signal on Channel 2 of the AO 12B2 Option Card proportional to output current The desired signal level is 10 vo...
Page 16: ...ted Kingdom Phone 44 12 3673 5000 Fax 44 12 3645 8182 YASKAWA ELECTRIC KOREA CORPORATION Paik Nam Bldg 901 188 3 1 Ga Euljiro Joong Gu Seoul Korea Phone 82 2 776 7844 Fax 82 2 753 2639 YASKAWA ELECTRI...