5.
Save, compile and transfer your project.
13.7.5
Deployment as PROFIBUS DP slave
The following section describes how to use the PROFIBUS part as an "intelligent" DP
slave on master systems. Execute the following steps:
1.
Configure a station with a CPU with DP master mode.
2.
Network with PROFIBUS
3.
Configure another station with a CPU with DP slave operating mode.
4.
Network with PROFIBUS and assign the DP slave to the DP master.
5.
Configure the I/O areas for the slave part.
ð
The configuration is automatically adapted to the DP master.
6.
Save, translate and transfer the respective project into the corresponding master or
slave CPU.
1.
Start the Siemens TIA Portal and configure a CPU.
2.
Designate the station as "... DP master".
3.
Integrate the modules according to the hardware configuration of the master
system.
4.
Select the PROFIBUS interface of the master CPU and select
‘Context menu
è
Properties’
.
ð
The
‘Properties’
dialog is shown.
5.
Set at
interface
: Type "PROFIBUS".
6.
Connect to PROFIBUS and preset an address (e.g. 2).
7.
Switch at Operating mode to "DP master".
Fast introduction
Configuration of the
master part
VIPA System SLIO
Configuration with TIA Portal
TIA Portal - Option: Deployment PROFIBUS communication > Deployment as PROFIBUS DP slave
HB300 | CPU | 013-CCF0R00 | en | 19-30
318