![YASKAWA VIPA System SLIO Manual Download Page 296](http://html.mh-extra.com/html/yaskawa/vipa-system-slio/vipa-system-slio_manual_907132296.webp)
13.2 TIA Portal - Functional limitations
Please note that the performance data of the CPU from VIPA is limited to the perform-
ance data of the Siemens CPU used for the configuration.
Due to the system
‘Upload device as new station...’
is currently not supported. Instead,
use the
backup
and
restore
functions in the Siemens TIA Portal:
1.
To
backup
an online connected CPU, select
‘Online
è
Backup from online device’
.
ð
A
backup
object is created and stored in the
project navigation
at
‘Online
backups’
. The backup contains all blocks of the project and the current device
status.
2.
To
restore
into an online connected CPU it must be overall reset first. Then click in
the
project navigation
under
‘Online backups’
on the created
backup
and select
‘Context menu
è
Download to device’
.
ð
The backup data is transferred online to the CPU.
Due to the system, online blocks of CPUs connected via
‘Accessible devices’
are cur-
rently not listed.
13.3 TIA Portal - Hardware configuration - CPU
The hardware configuration of the CPU and its plugged modules happens in the Siemens
TIA Portal by means of a virtual PROFINET IO device. For the PROFINET interface is
standardized software sided, the functionality is guaranteed by including a GSDML file
into the Siemens TIA Portal.
The hardware configuration of the CPU is divided into the following parts:
n
Installation PROFINET IO device
‘VIPA SLIO System’
n
Configuration Siemens CPU
n
Connection SLIO CPU as PROFINET IO device
The installation of the PROFINET IO devices
‘VIPA SLIO System’
happens in the hard-
ware catalog with the following approach:
1.
Go to the service area of www.vipa.com.
2.
Load from the download area at
‘Config files
è
PROFINET’
the according file for
your System SLIO.
3.
Extract the file into your working directory.
4.
Start the Siemens TIA Portal.
5.
Close all the projects.
6.
Switch to the
Project view
.
7.
Select
‘Options
è
Install general station description file (GSD)’
.
8.
Navigate to your working directory and install the according GSDML file.
ð
After the installation the hardware catalog is refreshed and the Siemens TIA
Portal is finished.
After restarting the Siemens TIA Portal the according PROFINET IO device can
be found at
Other field devices > PROFINET > IO > VIPA GmbH > VIPA SLIO
System
.
Limitation of performance
data
No ‘Upload device as new
station...’
No online blocks
Overview
Installation PROFINET IO
device ‘VIPA SLIO
System’
VIPA System SLIO
Configuration with TIA Portal
TIA Portal - Hardware configuration - CPU
HB300 | CPU | 013-CCF0R00 | en | 19-30
296