4.5 Diagnostics and interrupt
Via the parameterization you may activate a diagnostic interrupt for
the module. With a diagnostic interrupt the module serves for diag-
nostic data for diagnostic interrupt
incoming
. As soon as the reason for
releasing a diagnostic interrupt is no longer present, the diagnostic
interrupt
going
automatically takes place. Within this time window (1.
diagnostic interrupt
incoming
until last diagnostic interrupt
going
) the MF-
LED of the module is on.
Event
Process
interrupt
Diagnostics
interrupt
parameterizable
Encoder power supply is missing *
-
X
X
*) The module may only send a diagnostic interrupt in case of missing encoder power supply, if this received its parameters before. If the encoder
power supply is already missing during startup, the module does not send an diagnostic interrupt!
DS - Record set for access via CPU, PROFIBUS and PROFINET.
The access happens by DS 01h. Additionally the first 4 bytes
may be accessed by DS 00h.
IX - Index for access via CANopen. The access happens by IX
2F01h. Additionally the first 4 bytes may be accessed by IX
2F00h.
SX - Subindex (5005h) for access via EtherCAT.
More can be found in the according manual of your bus coupler.
Overview
Diagnostic data
VIPA System SLIO FM 050S
Deployment
Diagnostics and interrupt
HB300 | FM | 050-1BS00 | GB | 15-11