Summary of Contents for Varispeed f7

Page 1: ...oration Inverter SIO Driver 1 System Configuration 3 2 External Devices Selection 8 3 Communication Settings 9 4 Setup Items 45 5 Cable Diagrams 49 6 Supported Device 61 7 Device Code and Address Code...

Page 2: ...vice Selection Select a model series of the External Device and its connection method 2 External Devices Selection page 8 3 Communication Settings This section shows setting examples for communicating...

Page 3: ...interface card RS 422 485 4wire Setting Example 5 page 17 Cable Diagram 1 page 49 RS 422 485 2wire Setting Example 6 page 19 Cable Diagram 2 page 54 VS mini V7 VS 606V7 CIMR V7 A Terminal Block on the...

Page 4: ...39 Cable Diagram 2 page 54 J1000 CIMR JA A Terminal Block on the SI 485 J RS 422 485 interface card RS 422 485 4wire Setting Example 17 page 41 Cable Diagram 1 page 49 RS 422 485 2wire Setting Example...

Page 5: ...er SIO Driver GP Pro EX Device PLC Connection Manual 5 Connection Configuration 1 1 Connection 1 n Connection Display External Device Display External Device External Device External Device Maximum 16...

Page 6: ...COM2 1 COM3 2 COM4 2 Set up the SIO type with the DIP switch Please set up as follows according to SIO type to be used COM3 2 COM3 2 PS 3711A COM1 1 COM2 2 COM2 2 COM2 2 PL 3000B PL 3600T PL 3600K PL...

Page 7: ...RD RXD None 7 OFF Short circuit of SDA TXA and RDA RXA Not available 8 OFF Short circuit of SDB TXB and RDB RXB Not available 9 OFF RS RTS Auto control mode Disabled 10 OFF DIP switch Setting Descrip...

Page 8: ...to be connected Select YASKAWA Electric Corporation Series Select a model series of the External Device to be connected and connection method Select INVERTER SIO In System configuration check to make...

Page 9: ...Settings This section provides examples of communication settings recommended by Pro face for the Display and the External Device 3 1 Setting Example 1 GP Pro EX Settings Communication Settings To di...

Page 10: ...on the front of the inverter Refer to your External Device manual for details 1 Press the MENU key to select Programming 2 Press the DATA ENTER key 3 Press the Up key to display the parameter you wan...

Page 11: ...System Settings workspace select Device PLC Device Setting To display the Individual Device Settings dialog box select the external device and click Setting from Device Specific Settings in the Device...

Page 12: ...3 Press the Up key to display the parameter you want to set 4 Press the DATA ENTER key 5 Press the Up Down or Shift RESET key to display the setting value 6 Press the DATA ENTER key 7 Reboot the Exte...

Page 13: ...System Settings workspace select Device PLC Device Setting To display the Individual Device Settings dialog box select the external device and click Setting from Device Specific Settings in the Device...

Page 14: ...3 Press the Up key to display the parameter you want to set 4 Press the DATA ENTER key 5 Press the Up Down or Shift RESET key to display the setting value 6 Press the DATA ENTER key 7 Reboot the Exte...

Page 15: ...System Settings workspace select Device PLC Device Setting To display the Individual Device Settings dialog box select the external device and click Setting from Device Specific Settings in the Device...

Page 16: ...3 Press the Up key to display the parameter you want to set 4 Press the DATA ENTER key 5 Press the Up Down or Shift RESET key to display the setting value 6 Press the DATA ENTER key 7 Reboot the Exte...

Page 17: ...System Settings workspace select Device PLC Device Setting To display the Individual Device Settings dialog box select the external device and click Setting from Device Specific Settings in the Device...

Page 18: ...select PRGM 2 Press the Up key to display the parameter you want to set 3 Press the DATA ENTER key 4 Press the Up or Down key to display the setting value 5 Press the DATA ENTER key 6 Reboot the Exte...

Page 19: ...om the System Settings workspace select Device PLC To display the Individual Device Settings dialog box select the external device and click Setting from Device Specific Settings in the Device PLC win...

Page 20: ...select PRGM 2 Press the Up key to display the parameter you want to set 3 Press the DATA ENTER key 4 Press the Up or Down key to display the setting value 5 Press the DATA ENTER key 6 Reboot the Exte...

Page 21: ...System Settings workspace select Device PLC Device Setting To display the Individual Device Settings dialog box select the external device and click Setting from Device Specific Settings in the Device...

Page 22: ...elect PRGM 2 Press the Up key to display the parameter you want to set 3 Press the DATA ENTER key 4 Press the Up or Down key to display the setting value 5 Press the DATA ENTER key 6 Reboot the Extern...

Page 23: ...System Settings workspace select Device PLC Device Setting To display the Individual Device Settings dialog box select the external device and click Setting from Device Specific Settings in the Device...

Page 24: ...elect PRGM 2 Press the Up key to display the parameter you want to set 3 Press the DATA ENTER key 4 Press the Up or Down key to display the setting value 5 Press the DATA ENTER key 6 Reboot the Extern...

Page 25: ...System Settings workspace select Device PLC Device Setting To display the Individual Device Settings dialog box select the external device and click Setting from Device Specific Settings in the Device...

Page 26: ...3 Press the Up key to display the parameter you want to set 4 Press the DATA ENTER key 5 Press the Up Down or Shift RESET key to display the setting value 6 Press the DATA ENTER key 7 Reboot the Exte...

Page 27: ...System Settings workspace select Device PLC Device Setting To display the Individual Device Settings dialog box select the external device and click Setting from Device Specific Settings in the Devic...

Page 28: ...3 Press the Up key to display the parameter you want to set 4 Press the DATA ENTER key 5 Press the Up Down or Shift RESET key to display the setting value 6 Press the DATA ENTER key 7 Reboot the Exte...

Page 29: ...System Settings workspace select Device PLC Device Setting To display the Individual Device Settings dialog box select the external device and click Setting from Device Specific Settings in the Devic...

Page 30: ...ress the Up or Down key to display the parameter you want to set 4 Press the DATA ENTER key 5 Press the Up Down or Shift RESET key to display the setting value 6 Press the DATA ENTER key 7 Reboot the...

Page 31: ...System Settings workspace select Device PLC Device Setting To display the Individual Device Settings dialog box select the external device and click Setting from Device Specific Settings in the Devic...

Page 32: ...ress the Up or Down key to display the parameter you want to set 4 Press the DATA ENTER key 5 Press the Up Down or Shift RESET key to display the setting value 6 Press the DATA ENTER key 7 Reboot the...

Page 33: ...System Settings workspace select Device PLC Device Setting To display the Individual Device Settings dialog box select the external device and click Setting from Device Specific Settings in the Devic...

Page 34: ...3 Press the Up key to display the parameter you want to set 4 Press the DATA ENTER key 5 Press the Up Down or Shift RESET key to display the setting value 6 Press the DATA ENTER key 7 Reboot the Exte...

Page 35: ...System Settings workspace select Device PLC Device Setting To display the Individual Device Settings dialog box select the external device and click Setting from Device Specific Settings in the Devic...

Page 36: ...3 Press the Up key to display the parameter you want to set 4 Press the DATA ENTER key 5 Press the Up Down or Shift RESET key to display the setting value 6 Press the DATA ENTER key 7 Reboot the Exte...

Page 37: ...System Settings workspace select Device PLC Device Setting To display the Individual Device Settings dialog box select the external device and click Setting from Device Specific Settings in the Devic...

Page 38: ...s the ENTER key 5 Press the Up Down or Shift RESET key to display the setting value 6 Press the ENTER key 7 Reboot the External Device This completes the setting of the External Device Parameter No Se...

Page 39: ...System Settings workspace select Device PLC Device Setting To display the Individual Device Settings dialog box select the external device and click Setting from Device Specific Settings in the Devic...

Page 40: ...s the ENTER key 5 Press the Up Down or Shift RESET key to display the setting value 6 Press the ENTER key 7 Reboot the External Device This completes the setting of the External Device Parameter No Se...

Page 41: ...System Settings workspace select Device PLC Device Setting To display the Individual Device Settings dialog box select the external device and click Setting from Device Specific Settings in the Devic...

Page 42: ...nt to set 4 Press the ENTER key 5 Press the Up Down or RESET key to display the setting value 6 Press the ENTER key 7 Reboot the External Device This completes the setting of the External Device Param...

Page 43: ...System Settings workspace select Device PLC Device Setting To display the Individual Device Settings dialog box select the external device and click Setting from Device Specific Settings in the Devic...

Page 44: ...nt to set 4 Press the ENTER key 5 Press the Up Down or RESET key to display the setting value 6 Press the ENTER key 7 Reboot the External Device This completes the setting of the External Device Param...

Page 45: ...workspace select Device PLC Setup Items Setup Description SIO Type Select the SIO type to communicate with the External Device In the communication settings set SIO Type correctly according to the se...

Page 46: ...control method to prevent overflow of transmission and reception data Timeout Use an integer from 1 to 127 to enter the time s for which the Display waits for the response from the External Device Ret...

Page 47: ...g Manual 2 2 Off line Mode Setup Items Setup Description SIO Type Select the SIO type to communicate with the External Device In the communication settings set SIO Type correctly according to the seri...

Page 48: ...the response from the External Device Retry In case of no response from the External Device use an integer from 0 to 255 to enter how many times the Display retransmits the command Wait To Send Use a...

Page 49: ...to the SG design your system to avoid short circuit loops Connect an isolation unit if the communication is not stable due to noise or other factors Cable Diagram 1 Display Connection Port Cable Remar...

Page 50: ...n the External Device Turn on the termination resistor switch on the External Device located at the end Signal name RDB SDB CA3 ADPCOM 01 CA3 ADPTRM 01 Display Display Terminal Block Shield RDA SDA TR...

Page 51: ...ted at the end Display 100 1 2W Signal name SDA 3 RDB 2 SG 5 4 ERA SDB ERB 7 9 CSB 6 RDA 1 CSA 8 Display D Sub 9 pin socket Terminal resistance Pin FG Shell Shield Signal name S S R Terminal Block Ext...

Page 52: ...External Device Turn on the termination resistor switch on the External Device located at the end Signal name RDB SDB CA4 ADPONL 01 CA3 ADPTRM 01 Display Display Terminal Block Shield RDA SDA TRM User...

Page 53: ...tch on the External Device located at the end Signal name RDB SDB TRMTX CA4 ADPONL 01 Display Display D Sub 9 pin plug RDA SDA TRMRX User created cable 2 9 1 Pin 7 3 8 Signal name S S R Terminal Block...

Page 54: ...face CA3 ADPTRM 01 User created cable Cable length 50m or less B User created cable GP 1 COM2 C Online adapter by Pro face CA4 ADPONL 01 Terminal block conversion adapter by Pro face CA3 ADPTRM 01 Us...

Page 55: ...n the External Device Turn on the termination resistor switch on the External Device located at the end Signal name RDB SDB CA3 ADPCOM 01 CA3 ADPTRM 01 Display Display Terminal Block RDA SDA User crea...

Page 56: ...ted at the end Shield Signal name S S R Terminal Block External Device R Display 100 1 2W Signal name SDA 3 RDB 2 SG 5 4 ERA SDB ERB 7 9 CSB 6 RDA 1 CSA 8 Display D Sub 9 pin socket Terminal resistanc...

Page 57: ...External Device Turn on the termination resistor switch on the External Device located at the end Signal name RDB SDB CA4 ADPONL 01 CA3 ADPTRM 01 Display Display Terminal Block RDA SDA User created ca...

Page 58: ...tch on the External Device located at the end User created cable Shield Signal name S S R Terminal Block External Device R Signal name SDA 3 RDB 7 TRMTX 9 5 SG SDB 8 FG RDA 2 Display D Sub 9 pin plug...

Page 59: ...n the External Device Turn on the termination resistor switch on the External Device located at the end Signal name RDB SDB CA3 ADPCOM 01 CA3 ADPTRM 01 Display Display Terminal Block RDA SDA User crea...

Page 60: ...at the end Display Signal name NC 3 DATA 2 GND SG 5 4 ERA NC ERB 7 9 CSB 6 DATA 1 CSA 8 Display D Sub 9 pin socket Pin FG Shell Shield Signal name S S R Terminal Block External Device R 100 1 2W Termi...

Page 61: ...on error to appear when the readout command is executed Register 1 0000 1959 If you use a device set the address to the MEMOBUS register No corresponding to the parameter No Refer to your External Dev...

Page 62: ...ction Manual 62 7 Device Code and Address Code Use device code and address code when you set Device Type Address for the address type of the data display or other devices Device Device Name Device Cod...

Page 63: ...related to an error that has occurred Error Occurrence Area Displays the IP address or device address of the External Device where an error has occurred or error codes received from the External Devi...

Page 64: ...Inverter SIO Driver GP Pro EX Device PLC Connection Manual 64...