2
□
0154F, 2
□
0192F, 4
□
0156F, and 4
□
0180F
4
□
0720A to 4
□
0930A,
and Harmonic Filter Module
2
□
0154A, 2
□
0192A, 2
□
0248,
4
□
0156A, 4
□
0180A, and 4
□
0216 to 4
□
0590,
Figure 2.5 Horizontal Suspension of Drive Model 2
o
0154
n
Vertical Suspension of the Drive and Harmonic Filter Module
Follow the procedure described below when suspending the drive or harmonic filter module with eye bolts or hanging brackets.
Drive Models 2
o
0028 to 2
o
0130 and 4
o
0011 to 4
o
0124
WARNING! Crush Hazard. Use an adequate length of wire to ensure a 50° or wider suspension angle as illustrated in
maximum allowable load of the eye bolts cannot be guaranteed when the drive or harmonic filter module is suspended with the wires at
angles less than 50°. Failure to comply may result in serious injury or death from falling equipment.
1.
Pass wire through the holes of the two eye bolts.
Suspending angle:
50° or greater
Figure 2.6 Suspension Using Wires and Eye Bolts
2.
Gradually take up the slack in the wires and hoist the drive or harmonic filter module after the wires are stretched tight.
3.
Lower the drive or harmonic filter module when ready to install in the enclosure panel. Stop lowering when near the floor,
then slowly begin lowering the drive or harmonic filter module again until the drive or harmonic filter module is placed
correctly.
Drive Models 2
o
0154 to 2
o
0248 and 4
o
0156 to 4
o
0414