No.
Name
Unit
Default Settings
E5-24
Motor Induction Voltage
Constant 2 (Ke) (for PM
Motors)
mV/
(r/min)
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output
Frequency
Hz
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
E1-05
Maximum Voltage
V
190.0
190.0
190.0
190.0
190.0
190.0
190.0
190.0
E1-06
Base Frequency
Hz
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
E1-09
Minimum Output
Frequency
Hz
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
C5-17
Motor Inertia
kgm
2
0.046
0.55
0.064
0.116
0.140
0.259
0.31
0.42
n5-02
Motor Acceleration Time
s
0.102
0.101
0.098
0.130
0.127
0.193
0.191
0.187
Table B.22 400 V, 1750 r/min Type Yaskawa SSR1 Series IPM Motor
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for
PM Motors)
−
1232
1233
1235
1236
1238
123A
123B
123D
Voltage Class
V
400
400
400
400
400
400
400
400
Rated Power
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
Rated Speed
r/min
1750
1750
1750
1750
1750
1750
1750
1750
E5-02
Motor Rated Power (for PM
Motors)
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11.0
E5-03
Motor Rated Current (for PM
Motors)
A
0.89
1.56
2.81
4.27
7.08
10.31
13.65
20.7
E5-04
Number of Motor Poles (for
PM Motors)
−
6
6
6
6
6
6
6
6
E5-05
Motor Stator Resistance (r1)
(for PM Motors)
Ω
25.370
9.136
6.010
3.297
1.798
0.982
0.786
0.349
E5-06
Motor d-Axis Inductance
(Ld) (for PM Motors)
mH
169.00
92.08
67.71
34.40
32.93
22.7
16.49
13.17
E5-07
Motor q-Axis Inductance
(Lq) (for PM Motors)
mH
197.50
119.56
81.71
54.00
37.70
26.80
23.46
15.60
E5-09
Motor Induction Voltage
Constant 1 (Ke) (for PM
Motors)
mVs
/rad
392.6
440.6
478.3
466.3
478.8
478.1
520.0
481.5
E5-24
Motor Induction Voltage
Constant 2 (Ke) (for PM
Motors)
mV/
(r/min)
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output Frequency
Hz
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
E1-05
Maximum Voltage
V
380.0
380.0
380.0
380.0
380.0
380.0
380.0
380.0
E1-06
Base Frequency
Hz
87.5
87.5
87.5
87.5
87.5
87.5
87.5
87.5
E1-09
Minimum Output Frequency
Hz
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
C5-17
Motor Inertia
kgm
2
0.0011
0.0017
0.0023
0.0043
0.0083
0.014
0.017
0.027
n5-02
Motor Acceleration Time
s
0.092
0.076
0.052
0.066
0.075
0.083
0.077
0.084
Table B.23 400 V, 1750 r/min Type Yaskawa SSR1 Series IPM Motor
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for
PM Motors)
−
123E
123F
1240
1242
1243
1244
1245
1246
Voltage Class
V
400
400
400
400
400
400
400
400
Rated Power
kW
15
18
22
30
37
45
55
75
Rated Speed
r/min
1750
1750
1750
1750
1750
1750
1750
1750
E5-02
Motor Rated Power (for PM
Motors)
kW
15
18.50
22.00
30.00
37.00
45.00
55.00
75.00
E5-03
Motor Rated Current (for PM
Motors)
A
27.5
33.4
39.8
52.0
65.8
77.5
92.7
126.6
E5-04
Number of Motor Poles (for
PM Motors)
−
6
6
6
6
6
6
6
6
E5-05
Motor Stator Resistance (r1)
(for PM Motors)
Ω
0.272
0.207
0.148
0.235
0.079
0.054
0.049
0.029
B.19 Parameters Changed by Motor Code Selection (for PM Motors)
596
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual
Summary of Contents for U1000 iQpump Drive
Page 705: ......