No.
Name
Unit
Default Settings
–
Drive Model
–
4
o
0034
4
o
0040
4
o
0052
4
o
0065
C6-01
Drive Duty Selection
–
HD
ND
HD
ND
HD
ND
HD
ND
o2-04
Drive Model Selection
Hex.
9C
9D
9E
9F
E2-11
(E4-11)
Motor Rated Output
kW
(HP)
15 (20) 18.5 (25) 18.5 (25) 22 (30)
22 (30)
30 (40)
30 (40)
37 (50)
E5-01
Motor Code Selection (for PM Motors)
Hex.
123D
123D
123E
123E
123F
123F
1240
1240
L2-02
Momentary Power Loss Ride-Thru Time
s
0.9
1
1
1
1
1
1
1.1
L2-03
Momentary Power Loss Minimum
Baseblock Time
s
0.3
0.6
0.6
0.6
0.6
0.6
0.6
0.6
L2-04
Momentary Power Loss Voltage Recovery
Time
s
300
300
300
300
300
300
300
300
L2-21
Low Input Voltage Detection Level
V
300
300
300
300
300
300
300
300
L8-02
Overheat Alarm Level
°C
130
130
130
130
130
130
130
130
L8-35
Installation Method Selection
–
0
0
0
0
0
0
0
0
L8-38
Carrier Frequency Reduction Selection
–
1
1
1
1
1
1
1
1
n1-03
Hunting Prevention Time Constant
ms
10
10
10
10
10
10
10
10
n5-02
Motor Acceleration Time
s
0.265
0.244
0.244
0.317
0.317
0.355
0.355
0.323
Table B.14 400 V Class Drives Default Settings by Drive Model Selection and ND/HD Settings
No.
Name
Unit
Default Settings
–
Drive Model
–
4
o
0077
4
o
0096
4
o
0124
4
o
0156
C6-01
Drive Duty Selection
–
HD
ND
HD
ND
HD
ND
HD
ND
o2-04
Drive Model Selection
Hex.
A1
A2
A3
A4
E2-11
(E4-11)
Motor Rated Output
kW
(HP)
37 (50)
45 (60)
45 (60)
55 (75)
55 (75) 75 (100) 75 (100) 90 (125)
b3-04
V/f Gain during Speed Search
%
100
100
100
100
100
80
80
60
b3-06
Output Current 1 during Speed Search
–
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.7
b3-08
Current Control Gain during Speed Search
(Speed Estimation Type)
–
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.8
b8-03
Energy Saving Control Filter Time Constant
s
0.50
0.50
0.50
0.50
0.50
2.00
2.00
2.00
b8-04
Energy Saving Coefficient Value
–
92.54
76.32
76.32
71.56
71.56
67.2
67.2
46.2
C5-17 (C5-37) Motor Inertia
kgm
2
0.220
0.273
0.273
0.333
0.333
0.490
0.490
0.900
C6-02
Carrier Frequency Selection
–
1
1
1
1
1
1
1
1
E2-01 (E4-01) Motor Rated Current
A
52.3
65.6
65.6
79.7
79.7
95
95
130
E2-02 (E4-02) Motor Rated Slip
Hz
1.8
1.33
1.33
1.6
1.6
1.46
1.46
1.39
E2-03 (E4-03) Motor No-Load Current
A
10.9
19.1
19.1
22
22
24
24
36
E2-05 (E4-05) Motor Line-to-Line Resistance
Ω
0.269
0.155
0.155
0.122
0.122
0.088
0.088
0.092
E2-06 (E4-06) Motor Leakage Inductance
%
20.7
18.8
18.8
19.9
19.9
20
20
20
E2-10 (E4-10) Motor Iron Loss for Torque Compensation
W
750
925
925
1125
1125
1260
1260
1600
E5-01
Motor Code Selection (for PM Motors)
Hex.
1242
1242
1243
1243
1244
1244
1245
1245
L2-02
Momentary Power Loss Ride-Thru Time
s
1.1
1.1
1.1
1.2
1.2
1.2
1.2
1.3
L2-03
Momentary Power Loss Minimum
Baseblock Time
s
0.6
0.6
0.6
0.6
0.6
1
1
1
L2-04
Momentary Power Loss Voltage Recovery
Time
s
300
300
300
300
300
300
300
300
L2-21
Low Input Voltage Detection Level
V
300
300
300
300
300
300
300
300
L8-02
Overheat Alarm Level
°C
130
130
130
130
130
130
130
130
L8-35
Installation Method Selection
–
0
0
0
0
0
0
0
0
L8-38
Carrier Frequency Reduction Selection
–
1
1
1
1
1
1
1
1
n1-03
Hunting Prevention Time Constant
ms
10
10
10
10
10
10
30
30
n5-02
Motor Acceleration Time
s
0.323
0.32
0.32
0.387
0.387
0.317
0.317
0.533
B.18 Defaults by Drive Model and Duty Rating ND/HD
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual
591
B
Parameter List
Summary of Contents for U1000 iQpump Drive