B.11 n: Special Adjustments
The n parameters adjust more advanced performance characteristics such as Hunting Prevention, speed feedback detection,
and Online Tuning for motor line-to-line resistance.
u
n1: Hunting Prevention
No.
(Addr.
Hex)
Name
LCD Display
Description
Values
Page
n1-01
(0580)
Hunting Prevention
Selection
Hunt Prev Select
0: Disabled
1: Enabled
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
V/f
V/f w PG
0: Disabled
1: Enabled
Default: 1
Range: 0, 1
n1-02
(0581)
Hunting Prevention Gain
Setting
Hunt Prev Gain
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
V/f
V/f w PG
If the motor vibrates while lightly loaded, increase the gain by
0.1 until vibration ceases. If the motor stalls, decrease the gain
by 0.1 until the stalling ceases.
Default: 1.00
Min.: 0.00
Max.: 2.50
n1-03
(0582)
Hunting Prevention
Time Constant
Hunt Prev Time
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
V/f
V/f w PG
Sets the time constant used for Hunting Prevention.
Default:
Min.: 0 ms
Max.: 500 ms
n1-05
(0530)
Hunting Prevention Gain
while in Reverse
Hprev Gain @Rev
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
V/f
V/f w PG
Sets the gain used for Hunting Prevention. If set to 0, the gain
set to n1-02 is used for operation in reverse.
Default: 0.00
Min.: 0.00
Max.: 2.50
n1-09
(0BAD)
Vibration Suppression
Level
Vib Suppress Lvl
OLV/PM
OLV/PM
There is normally no need to change this parameter from the
default value.
Default: 2.00
Min.: 0.00
Max.: 10.00
n1-10
(0BAE)
Suppression Frequency Suppress Frq
OLV/PM
OLV/PM
There is normally no need to change this parameter from the
default value.
Default: 10.0 Hz
Min.: 5.0
Max.: 100.0
n1-11
(0BAF)
Suppression Auxiliary
Frequency
Suppress Sub-Frq
OLV/PM
OLV/PM
There is normally no need to change this parameter from the
default value.
Default: 20.0 Hz
Min.: 10.0
Max.: 50.0
n1-12
(0B1B)
Vibration Suppression
Time Constant
VibSuppress-Time
All Modes
There is normally no need to change this parameter from the
default value.
Default: 0 ms
Min.: 0
Max.: 1000
<1> Default setting is determined by parameter o2-04, Drive Model Selection.
<2> Available in drive software versions PRG: 1017 and later.
u
n2: Speed Feedback Detection Control (AFR) Tuning
No.
(Addr.
Hex)
Name
LCD Display
Description
Values
Page
n2-01
(0584)
Speed Feedback
Detection Control
(AFR) Gain
AFR Gain
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV
Sets the internal speed feedback detection control gain in the
automatic frequency regulator (AFR).
If hunting occurs, increase the set value. If response is low,
decrease the set value.
Default: 1.00
Min.: 0.00
Max.: 10.00
n2-02
(0585)
Speed Feedback
Detection Control
(AFR) Time Constant 1
AFR Time
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV
Sets the time constant used for speed feedback detection control
(AFR).
Default: 50 ms
Min.: 0
Max.: 2000
B.11 n: Special Adjustments