u
Model Number
n
Drive Models 2
o
0028 to 2
o
0248 and 4
o
0011 to 4
o
0930
CIMR-U U 4
A
A
0096
U A
U1000
Series
No.
Enclosure
Type
Design
Revision
Order
No.
Region
Code
U
USA
IP00
A
No.
Voltage Class
No.
Environmental
Specification
3-phase, 400 Vac
3-phase, 200 Vac
2
4
<1>
U
Humidity and dust
resistant
No.
Customized
Specifications
A
Without EMC
Noise Filter
Built-in EMC
Noise Filter
E
Built-in 24 V
Power Supply Unit
P
Built-in EMC Noise
Filter and 24 V
Refer to the tables below
Power Supply Unit
W
Figure 1.4 Drive Model Number Definition
<1> Drives with these specifications do not guarantee complete protection for the environmental conditions indicated.
n
Three-Phase 200 V Class
Table 1.3 Model Number and Specifications (200 V Class)
Normal Duty (ND) C6-01 = 1
Heavy Duty (HD) C6-01 = 0
Drive Model
Reference Motor
Capacity kW (HP)
Rated Output
Current A
Drive Model
Reference Motor
Capacity kW (HP)
Rated Output
Current A
2
o
0028
7.5 (10)
28
2
o
0028
5.5 (7.5)
22
2
o
0042
11 (15)
42
2
o
0042
7.5 (10)
28
2
o
0054
15 (20)
54
2
o
0054
11 (15)
42
2
o
0068
18.5 (25)
68
2
o
0068
15 (20)
54
2
o
0081
22 (30)
81
2
o
0081
18.5 (25)
68
2
o
0104
30 (40)
104
2
o
0104
22 (30)
81
2
o
0130
37 (50)
130
2
o
0130
30 (40)
104
2
o
0154
45 (60)
154
2
o
0154
37 (50)
130
2
o
0192
55 (75)
192
2
o
0192
45 (60)
154
2
o
0248
75 (100)
248
2
o
0248
55 (75)
192
n
Three-Phase 400 V Class
Table 1.4 Model Number and Specifications (400 V Class)
Normal Duty (ND) C6-01 = 1
Heavy Duty (HD) C6-01 = 0
Drive Model
Reference Motor
Capacity kW (HP)
Rated Output
Current A
Drive Model
Reference Motor
Capacity kW (HP)
Rated Output
Current A
4
o
0011
5.5 (7.5)
11
4
o
0011
3.7 (5)
9.6
4
o
0014
7.5 (10)
14
4
o
0014
5.5 (7.5)
11
4
o
0021
11 (15)
21
4
o
0021
7.5 (10)
14
1.3 Model Number and Nameplate Check
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual