B.3 Parameter Table
YASKAWA ELECTRIC
SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
415
Pa
ra
met
e
r Li
st
B
U1-04
(43H)
Control Method
0: V/f Control
1: V/f Control with PG
2: Open Loop Vector Control
3: Closed Loop Vector Control
5: Open Loop Vector Control for PM
6: Advanced Open Loop Vector Control for PM
7: Closed Loop Vector Control for PM
No signal output
available
–
–
U1-05
(44H)
Motor Speed
Displays the motor speed feedback. Display units are determined by o1-03.
10 V: Max Frequency 0.01 Hz
–
U1-06
(45H)
Output Voltage Reference
Displays the output voltage.
10 V: 200 Vrms
0.1 Vac
–
U1-07
(46H)
DC Bus Voltage
Displays the DC bus voltage.
10 V: 400 V
1 Vdc
–
U1-08
(47H)
Output Power
Displays the output power (this value is calculated internally).
10 V: Drive capacity
(Motor rated
capacity) kW
–
U1-09
(48H)
Torque Reference
Monitors the internal torque reference.
10 V: Motor rated
torque
0.1%
–
U1-10
(49H)
Input Terminal Status
Displays the input terminal status.
No signal output
available
–
–
U1-11
(4AH)
Output Terminal Status
Displays the output terminal status.
No signal output
available
–
–
No. (Addr.)
Name
Description
Analog Output
Level
Unit
Page
All Modes
OLV/PM
AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f
OLV
All Modes
All Modes
All Modes
OLV/PM
AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f
OLV
All Modes
Digital input 1
(terminal S1 enabled)
Digital input 2
(terminal S2 enabled)
Digital input 3
(terminal S3 enabled)
Digital input 4
(terminal S4 enabled)
Digital input 5
(terminal S5 enabled)
Digital input 6
(terminal S6 enabled)
Digital input 7
(terminal S7 enabled)
Digital input 8
(terminal S8 enabled)
All Modes
Multi-Function
Digital Output
(terminal M1-M2)
Multi-Function
Digital Output
(terminal M3-M4)
Multi-Function
Not Used
Digital Output
(terminal M5-M6)
Fault Relay
(terminal MA-MC closed
MA-MC open)