3.3 Forced Stop Setting for Triggers at Preset Positions
3-16
3.3
Forced Stop Setting for Triggers at Preset Positions
You can force-stop triggers at preset positions by setting bit 30 in the SVCMD_IO output area
to 1. This method can also be used to temporarily stop triggers at preset positions, such as
during origin return operations.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
N_CL
P_CL
P_PPI
V_PPI
Reserved (0).
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Reserved (0).
G-SEL
Bit 23
Bit 22
Bit 21
Bit 20
Bit 19
Bit 18
Bit 17
Bit 16
Reserved
(0).
SO3
SO2
SO1
BANK_SEL
Bit 31
Bit 30
Bit 29
Bit 28
Bit 27
Bit 26
Bit 25
Bit 24
Reserved
(0).
FOUT_STOP
Reserved
(0).
Reserved
(0).
Reserved (0).
Bit
Name
Description
Value
Setting
When Enabled
30
FOUT_STOP
Request to stop outputting
triggers at preset positions
0
None.
Rising edge
1
Request stopping
outputs at preset
positions.
This bit is used to request that the triggers at preset position outputs be stopped.