Sigma II User’s Manual
Chapter 9: Inspection, Maintenance, and Troubleshooting
9 - 10
A.32
A.32: Regenerative Overload
Display and Outputs
Note
OFF:
Output transistor is OFF (alarm state).
ON:
Output transistor is ON.
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Output
ALM Output
ALO1
ALO2
ALO3
ON
ON
OFF
OFF
Cause of the Problem
Solution
A
Regenerative power exceeds the
limit.
Use an external regenerative
resistor that matches the regener-
ative power capacity.
B
Alarm occurs although an exter-
nal regenerative resistor is used
and the temperature rise of the
regenerative resistor is small.
Correct parameter Pn600.
During servomotor operation.
A, B
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......