Sigma II User’s Manual
Chapter 7: Using the Digital Operator
7 - 42
7.2.9
Initializing Parameter Settings
This function is used to restore all the parameters to the default settings (standard
factory settings).
Follow the procedure below to initialize parameter settings.
Using the Hand-held Digital Operator
1.
Press the
DSPL/SET
key to select the auxiliary function mode.
2.
Select the parameter Fn005.
Press the
Left Arrow
or
Right Arrow
key to select the digit.
Press the
Up Arrow
or
Down Arrow
key to change the value.
3.
Press the
DATA/ENTER
key, and the display will be as shown below.
4.
Press the
DSPL/SET
key, and the display will be as shown below. The
parameters will be initialized.
5.
Press the
DATA/ENTER
key to return to the auxiliary function mode display.
This completes the initialization of parameter settings.
• Initialize the parameter settings with the servo OFF.
• After performing the procedure, cycle the power to restore all the parameters to the default settings.
IMPORTANT
Flashing for
one second
Flashing during
initialization
End
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......