Sigma II User’s Manual
Chapter 5: Parameter Settings and Functions
5-62
5.4 Setting Stop Functions
This section describes the procedure used to stop the servo amplifier properly.
5.4.1
Adjusting Offset
When the Servomotor Will Not Stop
The servomotor may rotate at very low speed and not stop even when 0V is specified
as the reference voltage for servo amplifier speed and torque control (analog
reference). This happens when the reference voltage from the host controller or
external circuit is slightly offset (in mV units). The servomotor will stop if this
offset is properly adjusted to 0V.
Reference Offset Adjustment
The following methods can be used to adjust the reference offset to 0V.
Note:
Use manual rather than automatic adjustment if a position control loop is formed in the host con-
troller.
See the following sections in
Chapter 7 Using the Digital Operator
for more details
on adjustment procedures.
Adjustment Method
Result
Automatic Adjustment of Reference Offset
The reference offset is automatically adjusted to 0V.
Manual Adjustment of Reference Offset
The reference offset can be set to a specified value.
Adjustment Method
Reference Source
Automatic Adjustment of Reference
Offset
7.2.3 Automatic Adjustment of the Speed and Torque Reference Offset
Manual Adjustment of Reference
Offset
7.2.4 Manual Adjustment of the Speed and Torque Reference Offset
Offset
Offset adjustment
Reference
voltage
Reference
voltage
Reference
speed or
torque
Reference
speed or
torque
Offset
corrected by
the servo
amplifier
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......