This section describes the basic settings for position control.
(1) Reference Pulse Form
Set the reference pulse form using Pn200.0.
(2) Input Filter Selection
Parameter
Reference Pulse
Form
Input
Pulse
Multi-
plier
Forward Run
Reference
Reverse Run
Reference
Pn200
n.
0
[Fac-
tory setting]
Sign + pulse train
(Positive logic)
n.
1
F Reverse pulse
train (Positive logic)
n.
2
Two-phase pulse train
with 90
phase differen-
tial
1
n.
3
2
n.
4
4
n.
5
Sign + pulse train
(Negative logic)
n.
6
F Reverse pulse
train (Negative logic)
H level
PULS
(CN1-7)
SIGN
(CN1-11)
L level
PULS
(CN1-7)
SIGN
(CN1-11)
L level
Reverse
(CN1-7)
Forward
(CN1-11)
L level
Reverse
(CN1-7)
Forward
(CN1-11)
90
ࠑ
Phase A
(CN1-7)
Phase B
1)
(CN1-1
90
ࠑ
Phase A
(CN1-7)
Phase B
1)
(CN1-1
L level
PULS
(CN1-7)
SIGN
(CN1-11)
H level
PULS
(CN1-7)
SIGN
(CN1-11)
H level
Reverse
(CN1-7)
Forward
(CN1-11)
H level
Reverse
(CN1-7)
Forward
(CN1-11)
Parameter
Meaning
When Enabled
Classification
Pn200
n.0
[Factory setting]
Uses the reference input filter for line driver signal.
(Up to 1 Mpps)
After restart
Setup
n.1
Uses the reference input filter for open-collector sig-
nal. (Up to 200 kpps)
n.2
Uses the reference input filter 2 for line driver signal.
(1 Mpps to 4 Mpps)
Summary of Contents for SGDV SERVOPACK
Page 23: ...www dadehpardazan ir 88594014 15 xxii ...
Page 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Page 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Page 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...