3.4 Mounting Interval
3.4.1 Installing One SERVOPACK in a Control Panel
3-5
3
SER
VOP
ACK Installation
3.4
Mounting Interval
3.4.1
Installing One SERVOPACK in a Control Panel
Provide the following spaces around the SERVOPACK.
*
For this dimension, ignore items protruding from the main body of the SERVOPACK.
3.4.2
Installing More Than One SERVOPACK in a Control
Panel
Provide the following spaces around the SERVOPACK, and install a cooling fan in the control
panel.
30 mm min.
30 mm min.
120 mm min.
*
120 mm min.
SERVOPACK
Install cooling fans above the SERVOPACKs so that hot spots do not occur around the SERVO-
PACKs.
SERVOPACK model
Cooling Fan Installation Conditions
10 mm above SERVOPACK’s Top Surface
SGD7S-
1R9D, 3R5D, 5R4D,
8R4D, 120D, 170D,
210D, 260D, 280D, 370D
Air speed: 1.0 m/s min.
Important
Fan
30 mm min.
30 mm min.
Fan
120 mm min.
120 mm min.
SERVOPACK
SERVOPACK
SERVOPACK
SERVOPACK