13.4 Utility Function (Fn
) Operations on the Panel Operator
13.4.19 Reset Option Module Configuration Error (Fn014)
13-27
13
Panel Displays and Panel Operator Pr
ocedur
es
13.4.19 Reset Option Module Configuration Error (Fn014)
Refer to the following section for information on this utility function other than the procedure.
12.2.6 Resetting Alarms Detected in Option Modules
13.4.20 Initialize Vibration Detection Level (Fn01B)
Refer to the following section for information on this utility function other than the procedure.
6.15 Initializing the Vibration Detection Level
Step
Panel Display after
Operation
Keys
Operation
1
Press the
MODE/SET
Key to enter Utility Function
Mode.
2
Press the
UP
Key or
DOWN
Key to display
Fn014
.
3
Press the
DATA/SHIFT
Key for approximately one sec-
ond. The display shown at the left will appear.
4
Press the
UP
Key or
DOWN
Key to select the Option
Module to be cleared.
5
Press the
MODE/SET
Key for approximately one sec-
ond. The display shown at the left will appear.
6
Press the
MODE/SET
Key again. The alarms in the
Option Module will be cleared.
donE
will flash on the display and the display shown
on the left will appear again.
7
Press the
DATA/SHIFT
Key for approximately one sec-
ond to return the display to
Fn014
.
8
To enable the change to the setting, turn the power supply to the SERVOPACK OFF and ON again
after clearing detected Option Module alarms has been completed.
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
Step
Panel Display after
Operation
Keys
Operation
1
Press the
MODE/SET
Key to enter Utility Function
Mode.
2
Press the
UP
Key or
DOWN
Key to display
Fn01b
.
3
Press the
DATA/SHIFT
Key for approximately one sec-
ond. The display shown at the left will appear.
4
(Flashing)
Press the
MODE/SET
Key for approximately one sec-
ond. The display shown on the left will flash and the
vibration level will be detected and updated.
Note: 1. Operate the SERVOPACK with the references that
will be used for actual operation.
2. If the Servomotor operates at 10% or less of the
maximum speed,
Error
will be displayed.
Continued on next page.
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/