13.2 Parameter (Pn
) Operations on the Panel Operator
13.2.2 Setting Parameters That Require Selection of Functions
13-7
13
Panel Displays and Panel Operator Pr
ocedur
es
Parameters with Settings of More Than Five Digits
The Panel Operator displays five digits. Settings of more than five digits are displayed as shown
in the following figure.
13.2.2
Setting Parameters That Require Selection of Functions
For parameters that require selection of functions, you can select the individual digits of the
numbers displayed on the Panel Operator to set the functions assigned to them.
The following example shows how to change the setting of Pn000 = n.
X
(Control Method
Selection) in Pn000 (Basic Function Selections 0) from speed control to position control.
The
s
etting of the parameter i
s
indicated by indicating
the digit
s
that are di
s
played and their numeric value
s
.
Upper
two digit
s
Pre
ss
the
DATA/SHIFT
Key.
Pre
ss
the
DATA/SHIFT
Key.
Lower
four digit
s
Pre
ss
the
DATA/SHIFT
Key.
Middle
two digit
s
Di
s
played for a negative number.
Step
Panel Display after
Operation
Keys
Operation
1
Press the
MODE/SET
Key to enter Parameter Setting
Mode.
If
Pn000
is not displayed, press the
UP
Key or
DOWN
Key to display
Pn000
.
2
Press the
DATA/SHIFT
Key for approximately one
second. The current setting of Pn000 will be dis-
played.
3
Press the
DATA/SHIFT
Key to move the digit that is
flashing.
(You can change the value of the digit that is flash-
ing.)
4
Press the
UP
Key once to change the display to
n.0010
.
(This changes the control method from speed control
to position control.)
5
(Flashing)
Press the
MODE/SET
Key. The display will flash.
The control method has now been changed from
speed control to position control.
6
Press the
DATA/SHIFT
Key for approximately one
second.
Pn000
is displayed again.
7
To enable the change to the setting, turn the power supply to the SERVOPACK OFF and ON again.
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/