4.3 Wiring the Power Supply to the SERVOPACK
4.3.2 Wiring Procedure for Main Circuit Connector
4
W
iring and Connecting
S
ER
VOP
ACK
s
4-15
4.3.2
Wiring Procedure for Main Circuit Connector
•
Required Items
1.
Remove the main circuit connector and motor connector from the SERVOPACK.
2.
Remove the sheath from the wire to connect.
3.
Open the wire insertion hole on the terminal connector with the tool. There are the fol-
lowing two ways to open the insertion hole. Use either method.
4.
Insert the conductor into the wire insertion hole. Then, remove the Spring Opener or flat-
blade screwdriver.
5.
Make all other connections in the same way.
6.
When you have completed wiring, attach the connectors to the SERVOPACK.
Required Item
Remarks
Spring Opener or Flat-
blade Screwdriver
•
Spring Opener
SERVOPACK accessory
(You can also use model 1981045-1 from Tyco Electronics Japan G.K.)
•
Flat-blade screwdriver
Commercially available screwdriver with tip width of 3.0 mm to 3.5 mm
Using a Spring Opener
Using a Flat-blade Screwdriver
Open the insertion hole with the Spring Opener as
shown in the figure.
Firmly insert a flat-blade screwdriver into the
screwdriver insertion hole to open the wire inser-
tion hole.
S
ervomotor connector
Main circuit
connector
Enlarged View
Lock
s
2. Pre
ss
in on the
lock
s
to remove
the connector
s
.
1. Pre
ss
in on
the lock.
8 mm to 9 mm
Wire
S
pring Opener