4.5 Connecting I/O Signals
4.5.1 I/O Signal Connector (CN1) Names and Functions
4-28
4.5
Connecting I/O Signals
4.5.1
I/O Signal Connector (CN1) Names and Functions
The following table gives the pin numbers, names, and functions the I/O signal pins for the
default settings.
Input Signals
Default settings are given in parentheses.
*
You can change the allocations. Refer to the following section for details.
6.1.1 Input Signal Allocations
Note: If forward drive prohibition or reverse drive prohibition is used, the SERVOPACK is stopped by software con-
trols. If the application does not satisfy the safety requirements, add external safety circuits as required.
Signal
Pin No.
Name
Function
Reference
/SI1
*
(P-OT)
7
General-purpose
Sequence Input 1 (For-
ward Drive Prohibit Input)
You can allocate the input signal to use
with a parameter.
(Stops Servomotor drive (to prevent over-
travel) when the moving part of the
machine exceeds the range of move-
ment.)
/SI2
*
(N-OT)
8
General-purpose
Sequence Input 2
(Reverse Drive Prohibit
Input)
/SI3
*
9
General-purpose
Sequence Input 3
You can allocate the input signal to use
with parameters.
(Used for general-purpose input.)
−
/SI4
*
(/Probe1)
10
General-purpose
Sequence Input 4
(Probe 1 Latch Input)
You can allocate the input signals to use
with parameters.
(Connect the external signals that latch
the current feedback pulse counter.)
−
/SI5
*
(/Probe2)
11
General-purpose
Sequence Input 5
(Probe 2 Latch Input)
/SI6
*
(/Home)
12
General-purpose
Sequence Input 6
(Home Switch Input)
You can allocate the input signal to use
with parameters.
(Connect the switch that starts homing.)
/SI0
*
13
General-purpose
Sequence Input 0
You can allocate the input signal to use
with a parameter.
(Used for general-purpose input.)
−
+24VIN
6
Sequence Input Signal
Power Supply Input
Inputs the sequence input signal power
supply.
Allowable voltage range: 24 VDC
±
20%
The 24-VDC power supply is not provided
by Yaskawa.
−
BAT+
14
Battery for Absolute
Encoder (+)
These are the pins to connect the abso-
lute encoder backup battery.
Do not connect these pins if you use the
Encoder Cable with a Battery Case.
−
BAT-
15
Battery for Absolute
Encoder (-)
TH
5
Linear Servomotor Over-
heat Protection Input
Inputs the overheat protection signal from
a Linear Servomotor.
−