14.15 Touch Probe Function
14-45
14
Object Dictionary
14.15
Touch Probe Function
Touch Probe Function (60B8 Hex)
This object sets the touch probes.
Data Description
Note: 1. Bits 0 to 7: For touch probe 1.
Bits 8 to 15: For touch probe 2.
2. Touch probe 1 cannot be used during execution of homing. If touch probe 1 was already enabled, it will be
disabled when homing is started.
3. If 1 is specified for bit 1 (i.e., if Continuous Trigger Mode is set), the setting of bit 2 (Trigger Selection Signal)
will be read each time the latch is started. To continuously latch with the same trigger signal, do not change
the status of bit 2.
Touch Probe Status (60B9 Hex)
This object gives the status of the touch probes.
Index
Subin-
dex
Name
Data
Type
Access
PDO
Mapping
Value
Saving to
EEPROM
60B8 hex
0
Touch probe func-
tion
UINT
RW
Yes
0 to 0xFFFF
(default: 0)
No
Bit
Value
Description
0
0
Disables touch probe 1.
1
Enables touch probe 1.
1
0
Single Trigger Mode (Latches the position at the first trigger event.)
1
Continuous Trigger Mode (Latches the position every trigger event.)
2
0
Triggers on probe 1 input (SERVOPACK CN1/Probe 1 (SI4) signal).
1
Triggers on encoder zero signal (phase C).
3
−
Reserved.
4
0
Stops sampling at touch probe 1.
1
Starts sampling at touch probe 1
5 to 7
−
Reserved.
8
0
Disables touch probe 2.
1
Enables touch probe 2.
9
0
Single Trigger Mode (Latches the position at the first trigger event.)
1
Continuous Trigger Mode (Latches the position every trigger event.)
10
0
Triggers on probe 2 input (SERVOPACK CN1/Probe 2 (SI5) signal).
1
Reserved.
11
−
Reserved.
12
0
Stops sampling at touch probe 2.
1
Starts sampling at touch probe 2
13 to 15
−
Reserved.
Index
Subin-
dex
Name
Data
Type
Access
PDO
Mapping
Value
Saving to
EEPROM
60B9 hex
0
Touch probe status
UINT
RO
Yes
−
No