11.4 Applications Examples for Safety Functions
11.4.3 Procedure
11-13
11
Safety Functions
11.4.3
Procedure
1
2
3
4
5
6
7
Request is received to open the guard.
If the motor is operating, a stop command is received from the
host controller, the motor stops, and the servo is turned OFF.
The guard is opened.
The worker leaves the guarded area after completing work.
The guard is closed.
Send the Servo ON command (Enable Operation command)
from the host controller.
The /HWBB1 and /HWBB2 signals turn OFF and the HWBB
operates. (Working inside the guard is enabled.)