7.6 Convenient Function to Use during Trial Operation
7.6.3 Test without a Motor
7-21
7
T
rial Operation and Actual Operation
7.6.3
Test without a Motor
A test without a motor is used to check the operation of the host controller and peripheral
devices by simulating the operation of the Servomotor in the SERVOPACK, i.e., without actually
operating a Servomotor. This test allows you to check wiring, debug the system, and verify
parameters to shorten the time required for setup work and to prevent damage to the machine
that may result from possible malfunctions. The operation of the motor can be checked with
this test regardless of whether the motor is actually connected or not.
Use Pn00C = n.
X to enable or disable the test without a motor.
Motor Information and Encoder Information
The motor and encoder information is used during tests without a motor. The source of the
information depends on the device connection status.
•
Rotary Servomotor
If you use fully-closed loop control, the external encoder information is also used.
Parameter
Meaning
When Enabled
Classification
Pn00C
(200C
hex)
n.
0
(default setting)
Disable tests without a motor.
After restart
Setup
n.
1
Enable tests without a motor.
An asterisk is displayed on the status display of the Digital Operator while a test without a
motor is being executed.
Motor Connection
Status
Information That Is Used
Source of Information
Connected
Motor information
Information in the motor that is connected
Encoder information
•
Encoder resolution
•
Encoder type
Not connected
Motor information
•
Rated motor speed
•
Maximum motor speed
•
Setting of Pn000 = n.X
(Rotary/Linear Startup
Selection When Encoder Is Not Connected)
•
Rated motor speed and maximum motor speed
The values previously saved in the SERVOPACK will
be used for the rated motor speed and maximum
motor speed.
Use the monitor displays (Un020: Rated Motor
Speed and Un021: Maximum Motor Speed) to check
the values.
Encoder information
•
Encoder resolution
•
Encoder type
•
Encoder resolution: Setting of Pn00C = n.
X
(Encoder Resolution for Tests without a Motor)
•
Encoder type: Setting of Pn00C = n.
X
(Encoder
Type Selection for Tests without a Motor)
External Encoder Connection
Status
Information That Is
Used
Source of Information
Connected
External encoder infor-
mation
•
Resolution
•
Encoder type
Information in the external encoder that is con-
nected
Not connected
•
Resolution: 256
•
Encoder type: Incremental encoder
Host controller
Reference
SERVOPACK
Reference
Response
Simulates operation
without a motor.
Response
Information