7.5 Trial Operation with the Servomotor Connected to the Machine
7.5.3 Operating Procedure
7-12
7.5.3
Operating Procedure
1.
Enable the overtravel signals.
5.10.2 Setting to Enable/Disable Overtravel
2.
Make the settings for the protective functions, such as the safety function, overtravel,
and the brake.
4.6 Connecting Safety Function Signals
5.10 Overtravel and Related Settings
3.
Turn OFF the power supplies to the SERVOPACK.
The control power supply and main circuit power supply will turn OFF.
4.
Couple the Servomotor to the machine.
5.
Turn ON the power supplies to the machine and host controller and turn ON the control
power supply and main circuit power supply to the SERVOPACK.
6.
Check the protective functions, such overtravel and the brake, to confirm that they
operate correctly.
Note: Enable activating an emergency stop so that the Servomotor can be stopped safely should an error
occur during the remainder of the procedure.
7.
Input the Enable Operation command from the host controller.
The servo will turn ON.
8.
Perform trial operation according to
7.4 Trial Operation with EtherCAT (CoE) Communi-
on page 7-10 and confirm that the same results are obtained as when trial oper-
ation was performed on the Servomotor without a load.
9.
If necessary, adjust the servo gain to improve the Servomotor response characteristics.
The Servomotor and machine may not be broken in completely for the trial operation. Therefore, let
the system run for a sufficient amount of time to ensure that it is properly broken in.
10.
For future maintenance, save the parameter settings with one of the following methods.
•
Use the S to save the parameters as a file.
•
Use the Parameter Copy Mode of the Digital Operator.
•
Record the settings manually.
This concludes the procedure for trial operation with both the machine and Servomotor.
To power
supply
Secure the motor flange to the
machine, and connect the
motor shaft to the load shaft
with a coupling or other means.
CN1, to host
controller
CN6A, to host
controller
CN1, to host
controller
CN6A, to host
controller
To power
supply