1.3 Part Names
1.3.1 SGD7S-R70A to -2R8A, SGD7S-R70F to -2R8F, and SGD7W-1R6A to -2R8A
1-4
1.3
Part Names
This section describes the connection terminals for an external dynamic brake resistor. All other
names are the same as those for a standard SERVOPACK. Refer to the standard SERVOPACK
product manual.
The external dynamic brake resistor terminals are used to connect an external dynamic brake
resistor. The terminal specifications and location depend on the SERVOPACK model. Refer to
the following section for the connection procedure.
4.2.5 Connecting Dynamic Brake Resistors
1.3.1
SGD7S-R70A to -2R8A, SGD7S-R70F to -2R8F, and
SGD7W-1R6A to -2R8A
These models do not support the dynamic brake hardware option specifications, so they do
not have external dynamic brake resistor terminals.
1.3.2
SGD7S-3R8A to -330A
The SGD7S-3R8A to -330A have external dynamic brake resistor terminals on the bottom of
the SERVOPACK.