5.3 Power Supply Type Settings for the Main Circuit and Control Circuit
5.3.1 AC Power Supply Input/DC Power Supply Input Setting
5-13
5
Device-
S
pecific
S
etting
s
5.3
Power Supply Type Settings for the Main Circuit and Control Circuit
A SERVOPACK can be operated on either an AC power supply input or DC power supply input
to the main and control circuits. If you select an AC power supply input, you can operate the
SERVOPACK on either a single-phase power supply input or a three-phase power supply input.
This section describes the settings related to the power supplies.
5.3.1
AC Power Supply Input/DC Power Supply Input Setting
Set Pn001 = n.
X
(Main Circuit Power Supply AC/DC Input Selection) to specify whether to
use an AC or DC power supply input for the main circuit power supply to the SERVOPACK.
If the setting of Pn001 = n.
X
does not agree with the actual power supply input, an A.330
alarm (Main Circuit Power Supply Wiring Error) will occur.
Refer to the following section for information on wiring the SERVOPACK.
3.5.4 Power Supply Wiring Diagrams
Examples of When an A.330 Alarm (Main Circuit Power Supply Wiring Error) Occurs
•
A DC power supply is input between the B1/
and
2 terminals, even though an AC
power supply is specified (Pn001 = n.
0
).
•
An AC power supply is input to the L1, L2, and L3 terminals, even though a DC power sup-
ply is specified (Pn001 = n.
1
).
Parameter
Meaning
When Enabled
Classification
Pn001
n.
0
(default set-
ting)
Use an AC power supply input.
After restart
Setup
n.
1
Use a DC power supply input.
WARNING
Connect the AC or DC power supplies to the specified SERVOPACK terminals.
•
Connect an AC power supply to the L1, L2, and L3 terminals and the L1C and L2C terminals on
the SERVOPACK.
•
Connect a DC power supply to the B1/
and
2 terminals and the L1C and L2C terminals on
the SERVOPACK.
There is a risk of failure or fire.
Always specify a DC power supply input (Pn001 = n.
1
) before you input DC power for
the main circuit power supply.
If you input DC power without specifying a DC power supply input (i.e., without setting Pn001 to
n.
1
), the SERVOPACK’s internal elements may burn and may cause fire or damage to the
equipment.
With a DC power supply input, time is required to discharge electricity after the main power
supply is turned OFF. A high residual voltage may remain in the SERVOPACK after the
power supply is turned OFF. Be careful not to get an electric shock.
Install fuses on the power supply line if you use DC power.
The Servomotor returns regenerative energy to the power supply. If you use a SERVOPACK
with a DC power supply input, regenerative energy is not processed. Process the regenera-
tive energy at the power supply.
Example
All Axes