1.5 List of Commands
1.5.3 Subcommands
1
MECHA
TROLINK-III Communication
S
etting
s
1-9
1.5.3
Subcommands
The standard servo profile subcommands used for
Σ
-7-Series SERVOPACKs are listed below.
1.5.4
Combinations of Main Commands and Subcommands
The combinations of main commands and subcommands are listed below. When an invalid
combination is specified, an alarm (SUBCMD_ALM = BH (A.95E)) occurs.
Category
Com-
mand
Code
Command
Command Name
Function
Reference
Servo
Com-
mands
00h
NOP
No operation com-
mand
Nothing is performed.
05h
ALM_RD
Read alarm/
warning command
Reads the current alarm or warning status,
and the alarm history.
06h
ALM_CLR
Clear alarm/
warning state com-
mand
Clears the current alarm or warning status,
and the alarm history.
1Dh
MEM_RD
Read memory com-
mand
Reads data from virtual memory.
1Eh
MEM_WR
Write memory com-
mand
Writes data to virtual memory.
30h
SMON
Monitor servo status
command
Monitors the SERVOPACK status.
40h
SVPRM_RD
Read servo parameter
command
Reads the specified servo parameter.
41h
SVPRM_WR
Write servo parameter
command
Writes the specified servo parameter.
Main Command
Subcommands
NOP
(00h)
ALM_RD
(05h)
ALM_
CLR
(06h)
MEM_
RD
(1Dh)
MEM_
WR
(1Eh)
SMON
(30h)
SVPRM
_RD
(40h)
SVPRM
_WR
(41h)
Com-
mon
Com-
mands
NOP (00h)
ID_RD (03h)
CONFIG (04h)
×
×
×
×
×
×
ALM_RD (05h)
×
×
×
×
×
×
ALM_CLR (06h)
×
×
×
×
×
×
SYNC_SET (0Dh)
×
×
×
×
×
×
CONNECT (0Eh)
×
×
×
×
×
×
×
DISCONNECT
(0Fh)
×
×
×
×
×
×
×
MEM_RD (1Dh)
×
×
×
×
×
×
MEM_WR (1Eh)
×
×
×
×
×
×
Continued on next page.