Setting 0: Inch of Water (WC)
Setting 1: Pounds per Square Inch (PSI)
Setting 2: Gallons per Minute (GPM)
Setting 3: Degrees Fahrenheit (F)
Setting 4: Cubic Feet per Minute (CFM)
Setting 5: Cubic Meters per Hour (CMH)
Setting 6: Liters per Hour (LPH)
Setting 7: Liters per Second (LPS)
Setting 8: Bar (Bar)
Setting 9: Pascals (Pa)
Setting 10: Degrees Celsius (C)
Setting 11: Meters (Mtr)
Setting 12: Feet (Ft)
Setting 13: Liters per Minute (LPN)
Setting 14: Cubic Meters per Minute (CMM)
Setting 15: Inches of Mercury (Hg)
Setting 24: Custom Units (determined by o1-13 to o1-15)
Setting 25: None
n
o1-10: User-Set Display Units Maximum Value
Determines the display value that is equal to the maximum output frequency.
No.
Name
Setting Range
Default
o1-10
User-Set Display Units Maximum Value
1 to 60000
Determined by
o1-03
n
o1-11: User-Set Display Units Decimal Display
Determines how many decimal points should be used to set and display the frequency reference.
No.
Name
Setting Range
Default
o1-11
User-Set Display Units Decimal Display
0 to 3
Determined by
o1-03
Setting 0: No Decimal Point
Setting 1: One Decimal Point
Setting 2: Two Decimal Points
Setting 3: Three Decimal Points
n
o1-13: Frequency Reference and Frequency Related Monitor Custom Units 1
Sets the first character of the customer-specified unit display when o1-03 is set to 3 and o1-09 is set to 24.
No.
Name
Setting Range
Default
o1-13
Frequency Reference and Frequency Related Monitor Custom Units
1
30 to 7A
41
n
o1-14: Frequency Reference and Frequency Related Monitor Custom Units 2
Sets the second character of the customer-specified unit display when o1-03 is set to 3 and o1-09 is set to 24.
No.
Name
Setting Range
Default
o1-14
Frequency Reference and Frequency Related Monitor Custom Units
2
30 to 7A
41
n
o1-15: Frequency Reference and Frequency Related Monitor Custom Units 3
Sets the third character of the customer-specified unit display when o1-03 is set to 3 and o1-09 is set to 24.
5.10 o: Operator Related Settings
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
269
5
Parameter Details