14.2 Procedure of External Resistance Calibration
14-4
HW0480311
HW0480311
14.2.2
Measuring the External Resistance Value
The external resistance is measured by panel operations. The following describe how to
measure the resistance value.
1.
Start-up of the resistance measurement mode
With the "Weld.Type" button pressed, turn ON the welding source main power supply.
The welding source starts up in the resistance measurement mode.
In the resistance measurement mode, the external resistance can be obtained by out-
putting the constant current of approx. 300 A and measuring the voltage required at
that time.
Fig. 24 Start-up of the Resistance Measurement Mode
V
A
Wire m/min
Type
ON
OFF
Record
Gas
Common PRM Select
PRM Select
PRM Set
Weld, Type
File No.1
File No.2
File No.3
User File Select
Power
Warning
Search
L
R
V
A
Wire m/min
Type
Record
Gas
Common PRM Select
PRM Select
PRM Set
Weld,Type
File No.1
File No.2
File No.3
User File Select
Power
Warning
Search
L
R
V/Set
A.W/S
In the resistance measurement
mode, the current command value
is set to "300 A".
Displays "r" which indicates
the resistance measurement mode.
c
While pressing "Weld, Type"
button,
d
turn ON the welding source
main power.