55
* Under normal conditions, the reduction gear units shall be greased only when the motor is
replaced. However, in case of severe working conditions (such as high duty, high speeds,
large payloads, etc.), the reduction gear units must be greased every 10,000 hours.
9.4
Tightening the screws
Hexagon socket head cap bolts are used in places where mechanical strength is required. (A
hexagon socket head cap bolt will be called a “bolt” in this manual.) These bolts are fastened
with the tightening torques shown in the following table.
When it is necessary to refasten these bolts in some procedures in this manual (except
special cases as noted), use a torque wrench so that the bolts are fastened with the
appropriate tightening torques as shown below.
Table 13: Greasing Popints
Greasing part
Greasing Interval
Grease
Refer to:
θ
1
θ
2
Reduction gear
units
In the replacement of motor*
SK-1A
Maintenance:
10.1 Replacing the
θ
1 reduction gear
unit
10.2 Replacing the
θ
2 reduction gear
unit
Z
Ball screw
spline unit
First time: after 50 km operation
2nd or more: after 100 km operation
AFB
Maintenance: 10.10 Greasing the Ball
Screw Spline Unit
U
Backlash-less
gear
In Z greasing
AFB
Following indication
Table 14: Tightening torque
Screw
Tightening torque
M3
245 Ncm
M4
490 Ncm
M5
980 Ncm
M6
1,760 Ncm
M8
3,720 Ncm
M10
7,350 Ncm
M12
12,740 Ncm
Summary of Contents for MOTOMAN MYS450L
Page 26: ...26 E1101000117GB01 MYS450L 5 3 Dimensions 4 5 12 1 200 6 7 8 9 10 3 11 Dimensions mm...
Page 40: ...40 E1101000117GB01 MYS450L 8 Electrical Equipment Specification 8 1 Signal cable BASE ARM2...
Page 41: ...MYS450L E1101000117GB01 41 8 2 Power cable BASE ARM2...
Page 60: ...60 E1101000117GB01 MYS450L...
Page 61: ...MYS450L E1101000117GB01 61...