7-1
176183-1CD
HW1483638
7
Disassembly and Reassembly of Wrist Unit
MH5S
(II)
/MH5F
7
Disassembly and Reassembly of Wrist Unit
• Refer to
Fig. 7-1 “Disassembly & Reassembly of Wrist Unit”
Disassembly
1. Turn OFF the DX100/DX200/FS100 power supply.
2. Unscrew the hexagon socket button head screws
and remove the
cover
.
3. Connect backup batteries with the B- and T-axes motors.
4. Disconnect the connectors of the B- and T-axes connected to the
internal wiring harness.
5. Unscrew the pan-head sems screws
, pull out the connected base
and disconnect the connected internal wiring harness and the air
hoses.
6. Unscrew the hexagon socket button head screws
and remove the
cover
. Unscrew the GT-SA bolts
and pull out the internal wiring
harness to the casing side. (Refer to
.)
7. Unscrew the GT-SA bolts
and remove the pipe
.
8. Remove the R-axis motor
. (Refer to
Reassembly of the R-Axis Motor”
.)
9. Remove the timing belt
Reassembly of R-Axis Timing Belt”
10. Unscrew the hexagon socket head cap screws
. With the removal
tap, remove the wrist unit.
11. Remove old sealing from each parts.
Reassembly
1. Apply Three Bond 1206C to the matching face between the casing and
the wrist unit
.
2. Mount the wrist unit
on the casing.
3. Attach the conical spring washers to the hexagon socket head cap
screws
and apply Three Bond 1206C to their thread parts. Then
tighten them with the tightening torque shown in
4. Mount the R-axis motor
. (Refer to
.)
5. Put the timing belt
on the pulley
. (Refer to
6. Mount the pipe
and tighten the GT-SA bolts
with the tightening
torque shown in
.
7. Connect the internal wiring harness to wire. (Refer to
.)
8. Tighten the GT-SA bolts
with the tightening torque shown in
.
9. Remove the backup batteries from the B- and T-axes motors.
NOTE
Refer to the following chapters in this manual as needed:
Chapter 2 “Notes for Maintenance”
,
Chapter 5 “Disassembly and Reassembly
.