3 Installation
3.1 Requirements
3-1
154771-1CD
HW0485080
3
Installation
3.1
Requirements
Prepare the power supply, the air supply, and the grounding according to the following
specifications.
Table 3-1 Specifications
No.
Item
Specifications
Remarks
1
Power supply
3-phase 200/220 VAC
(±10 % to -15 %)
50/60 Hz (±2 Hz)
5 kVA (at peak)
(Option)
3-phase 240/480/575VAC
(+10% to -15%)
50/60 Hz (±2 Hz)
5 kVA
2
Air supply
Spray ON/OFF
Gun-tilt switching
Pressurized explo-
sion proof enclosure
Required pressure: 0.35 MPa to
0.65 MPa
Capacity:
For turning the spray ON/OFF:
30 N/min
For switching the tilt of the gun:
30 N/min
For the pressurized explosion proof
30 N/min usually
1000 N/min when purging
Dryness: Freezing at -18
°
C
Use
dry air
for the
pressurized explosion-
proof construction.
3
Grounding
Grounding resistance:
100
ohm or less (Non I.S.
GND)
10
ohm or less (I.S. GND)
For the robot controller
Use dry air for the pressurized explosion-proof enclosure. Moisture in the air supply may
damage the electronic parts.
CAUTION
18 of 66