Setup
2.5 System Configuration
Weldcom Function: Arc
Welding Digital I/F
3. A confirmation dialog box appears. Select {YES}.
2.5.5 I/O Module Setting Check after Adding Virtual EW Module
Once the digital interface setting is confirmed, the virtual EW module
VEW01 is added as an I/O module.
The following explains the final checking process, not the setting
procedure, to add VEW01 as an I/O module at the time of completion of
the WELDCOM function setting.
1. In the WELDER SETUP and the DETAILED SETUP window, when the
settings are completed, the IO MODULE setting window automatically
appears.
– The virtual EW module, VEW01, is displayed.
2. Press [ENTER].
A confirmation dialog box appears. Select {YES}.
3. Select {AUTO} or {MANUAL} in the ALLOCATION MODE
A confirmation dialog box appears. Select {YES}.