12.9 o: Keypad-Related Settings
YASKAWA
SIEPYEULA5001C LA500 Technical Manual
349
•
o1-10 = 10000
•
o1-11 = 2 [User Units Decimal Position = 2 Dec (XXX.XX)]
■
o1-10: User Units Maximum Value
No.
(Hex.)
Name
Description
Default
(Range)
o1-10
(0520)
Expert
User Units Maximum Value
Sets the value that the drive shows as the maximum output frequency.
Determined by o1-03
(1 - 60000)
To display a maximum output frequency of 100.00, set parameters to these values:
•
o1-10 = 10000
•
o1-11 = 2 [User Units Decimal Position = Two Decimal Places (XXX.XX)]
Note:
Set
o1-03 = 3 [Frequency Display Unit Selection = User Units (o1-10 & o1-11)]
before you set
o1-10
and
o1-11
.
■
o1-11: User Units Decimal Position
No.
(Hex.)
Name
Description
Default
(Range)
o1-11
(0521)
Expert
User Units Decimal
Position
Sets the number of decimal places for frequency reference and monitor values.
Determined by o1-03
(0 - 3)
0 : No Decimal Places (XXXXX)
1 : One Decimal Places (XXXX.X)
2 : Two Decimal Places (XXX.XX)
3 : Three Decimal Places (XX.XXX)
Note:
Set
o1-03 = 3 [Frequency Display Unit Selection = User Units (o1-10 & o1-11)]
before you set
o1-10 [User Units Maximum Value]
and
o1-11
.
■
o1-24 to o1-29: Custom Monitor 1 to 6
No.
(Hex.)
Name
Description
Default
(Range)
o1-24 to o1-29:
(11AD - 11B2)
RUN
Custom Monitor 1 to 6
Sets a maximum of 6 monitors as user monitors. This parameter is only available when using an
LCD keypad.
o1-24: 101
o1-25: 102
o1-26: 103
o1-27 to o1-29: 0
(0, 101 - 999)
These parameters save the monitor items selected by the LCD keypad [Custom Monitor].
Note:
•
You can show a maximum of three selected monitors on one LCD keypad screen.
–
When you select only one monitor, the text size of this monitor increases. For example, when
o1-25 to o1-29 = 0
, the text size of the
monitor saved in o1-24 increases.
–
When you select two monitors, the text size of these monitors increase.
–
When you select four or more monitors, the fourth monitor and all additional monitors are shown on the next screens.
•
Monitors selected with
o1-24
to
o1-26
can be displayed as a bar graph, analog gauge, or trend plot.
–
Bar graph display: 3 monitors maximum
Select with
o1-24
,
o1-25
, and
o1-26
.
–
Analog gauge display: 1 monitor
Select with
o1-24
.
–
Trend plot display: 2 monitors
Select with
o1-24
and
o1-25
.
•
You can only set parameters
o1-24
to
o1-26
with analog output monitors.
•
You can set all monitors to parameters
o1-27
to
o1-29
.
V/f
OLV
V/f
OLV
V/f
OLV
Summary of Contents for LA500
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 10: ...10 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 18: ...i 3 Glossary 18 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 74: ...3 14 Wiring Checklist 74 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 164: ...6 1 MEMOBUS Modbus Communications 164 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 202: ...7 10 Troubleshooting Without Fault Display 202 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 218: ...8 6 Storage Guidelines 218 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 234: ...10 6 Peripheral Devices and Options 234 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 375: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 375...