4.2 Using the Digital Operator
♦ LO/RE LED and RUN LED Indications
Table 4.3 LO/RE LED and RUN LED Indications
LED
Lit
Flashing
Flashing Quickly
<
1
>
Off
W hen source o f the U p/Dow n com
mand is assigned to the digital oper
ator (LOCAL).
-
-
U p/Dow n command to be given from a device
other than the digital operator (REMOTE).
During run
• During deceleration to stop.
• W hen an U p/D ow n command is input
and speed reference is 0%.
• W hile the drive is set for LOCAL,
an U p/Dow n command was entered
to the input terminals after which the
drive was then switched to
REMOTE.
• An Up/Dow n command was entered
via the input terminals w hile not in
the Drive Mode.
• During deceleration when an
Emergency Stop command was
entered.
• The drive output is shut o ff by the
Safe D isable function.
• W hile the drive was running in the
REMOTE mode, the STOP key was
pushed.
During stop
ч r
t
Examples
Ш
■'Я
Ф к и м И
-
'
; ■' ’ Si
1
<1> R efer to
F ig u re 4.3
for the difference between “flashing” and “flashing quickly”
1 s
plashing -
quickly
|
O
n
ON
g
I O
n
|
[
o n
]
ON
ON
F ig u r e 4 .3 RUN LED S t a t u s a n d M e a n in g
Drive output speed
Up/Down
Speed setting
RUN LED
during stop | RUN
jSTOPI
1 R U N JSTOPI
10% !
0%
1
!
!
i
■
Opp
ON
o p p
o p p
plashing
F ig u r e 4 .4 RUN LED a n d D riv e O p e r a tio n