B.3 Parameter Table
■ n9: Current Detection Adjustments
No. (Addr.)
Name
n9-60
(64DH)
A /D Conversion Start Delay
Description
Sets a delay time for starting the current signal A /D conversion. This value seldom needs to be
changed.
Setting
Page
Default: <4>
Min: 0.0 |is
Max: 40.0 ^s
2 10
V/f
CLV/PM
<4> D efault setting is determined by the drive model (o2-04).
♦ o: Operator Related Parameters
The o parameters set up the digital operator displays.
■ o1: Digital Operator Display Selection
For more details on the digital operator displays, refer to
Digital Operator Display Unit Selection on page 91.
No. (Addr.)
Name
o1-01
(500H)
Drive M ode Unit Monitor
Selection
o1-02
(501H)
User Monitor Selection after
Power Up
o1-03
(502H)
D igital Operator Display Unit
Selection
o1-04
(503H)
V /f Pattern Setting Units
o1-10
(520H)
User-Set Display Units Maximum
Value
o1-11
(521H)
User-Set Display Units D ecim al
Display
o1-12
(739H)
Length Units
o1-20
(575H)
Traction Sheave Diameter
o1-21
(576H)
Roping Ratio
o1-22
(577H)
M echanical Gear Ratio
Description
Setting
Page
Default: 106 (Monitor
U 1-06)
Min: 105
Max: 699
211
Default: 1
Min: 1
Max: 5
211
Default: 1
Min: 0
Max: 6 <21>
211
Default: <5>
Min: 0
Max: 1
212
Default: <20>
Min: 1
Max: 60000
212
Default: <20>
Min: 0
Max: 3
212
Default: 0
Min: 0
Max: 1
212
Default: 400 mm <38>
Min: 100 mm
Max: 2000 mm <38>
212
Default: 2
Min: 1
Max: 4
213
Default: <5>
Min: 0.10
Max: 50.00
213
Selects the content o f the last monitor that is shown when scrolling through Drive Mode
display. Enter the last three digits o f the monitor parameter number to be displayed: U D - D Q
Speed reference (U 1-01)
Direction
Output speed (U 1-02)
Output current (U 1-03)
User-selected monitor (set by o1-01)
Sets the units the drive should use to display the frequency reference and motor speed monitors.
0.01 Hz
0.01% (100% = E1-04)
r/min (calculated using the number o f motor poles setting in E2-04, E4-04, or E5-04)
User-selected units (set by o1-10 and o1-11)
Elevator units 1 (speed in m/s, accel/decel rate and jerk in s)
Elevator units 2 (speed in m/s, accel/decel rate in m /s2, jerk in m/s3)
Elevator units 3 (speed in ft/min, accel/decel rate in ft/s2, jerk in ft/s3)
CLV
■
CLV/PM
0: Hz
1: r/min
These settings define the display values when o1-03 is set to 3.
o1-10 sets the display value that is equal to the maximum output frequency.
o1-11 sets the position o f the decimal position.
CLV
В
CLV/PM
0: Millim eter unit
1: Inch unit
CLV
В
CLV/PM
Sets the traction sheave diameter for display unit calculations.
CLV
В
CLV/PM
Sets the roping ratio.
1:1
1:2
1:3
1:4
CLV
В
CLV/PM
Sets the ratio o f the gear installed for display unit calculations.
V/f
V/f
V/f
V/f
V/f
<5> D efault setting is determined by the control mode (A1-02).
<20> This param eter appears w hen the drive displays user-set units (o1-03 = 3).
<21> The control mode determines the selections available. In V /f Control, only settings 1 through 3 are permitted.
<38> D efault setting and setting range changes when inches are selected for the length units (o1-12 = 1). The setting range becomes 3.70 to 78.00
inches, and the default becomes 15.70 inches.
IE
YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual
347
P
a
ra
m
e
te
r
L
is