5.10 o: Operator Related Settings
5.10 o: Operator Related Settings
These parameters control the various functions, features, and display o f the digital operator.
♦ o1: Digital Operator Display Selection
These parameters determine the data display on the digital operator.
■ o1-01: Drive Mode Unit Monitor Selection
When the drive is powered up, the monitor selected in parameter o1-02 appears first on the display. If o1-02 is set to 5,
o 1-01 can be used to change the content o f this monitor.
When using an LED operator, pressing the up arrow key will display the following data: speed reference ^ rotational
direction ^ output speed ^ output current ^ o 1-01 selection.
Parameter o1-01 selects the content of the last monitor in this sequence. There is no effect like this on an LCD operator.
No.
Name
Setting Range
Default
o1-01
Drive M ode Unit Monitor Selection
105 to 699
U 1-04 (Control M ode) to
U 6-99 (Option Monitor 20) <1>
106 (U 1-06)
<1> U 2 -D D and U 3 -D D param eters cannot be selected.
■ o1-02: User Monitor Selection after Power Up
Selects which monitor parameter is displayed upon power up. This is done by entering the 1П П part o f U1-DD . Certain
monitors are not available in some control modes.
Refer to U: Monitor Parameters on page 232
for a list o f monitors.
No.
Name
Setting Range
Default
o1-02
User Monitor Selection after Power Up
1 to 5
1
Setting 1: Speed reference (U1-01)
Setting 2: Motor direction
Setting 3: Output speed (U1-02)
Setting 4: Output current (U1-03)
Setting 5: User-selected m onitor (set by o1-01)
■ o1-03: Digital Operator Display Unit Selection
Sets the units used to display speed related settings and monitors as well as accel/decel rate settings and jerk settings.
Refer to
Digital Operator Display Unit Selection on page 91.
No.
Name
Setting Range
Default
o1-03
Digital Operator D isplay Unit Selection
0 to 6
1
Setting 0: 0.01 Hz units
Setting 1: 0.01% units (100% = max. output frequency)
Setting 2: r/min units (calculated by the max output frequency and the no. of m otor poles)
Setting 3: User-set units (use o1-10, o1-11)
Set o1-03 to 3 for user-set units, then set parameters o1-10 and o1-11.
Set the value use for the maximum frequency reference to o1-10. The placement o f the decimal point in this number
should be set to o 1- 11.
For example, to have the maximum output speed displayed as “ 100.00”, set the o1-10 = 1000 and o1-11 = 2 (i.e., 1000
with 2 decimal points).
Setting 4: Elevator units 1 (speed in m/s, accel/decel rate and jerk in s)
Setting 5: Elevator units 2 (speed in m/s, accel/decel rate in m/s2, jerk in m/s3)
Setting 6: Elevator units 3 (speed in ft/min, accel/decel rate in ft/s2, jerk in ft/s3)