5.7 H: Terminal Functions
5.7
H: Terminal Functions
H parameters are used to assign functions to the external terminals.
♦ H1: Multi-Function Digital Inputs
N O TIC E:
A lw a y s turn o ff the R U N c o m m a n d b e fo re c h a n g in g the s e ttin g o f p a ra m e te rs d 1 -1 8 (S p e e d R e fe re n c e S ele ctio n M ode), b1-
01 (S p e e d R e fe re n ce S election), o r
Н 1 - П П
(M u lti-F u n c tio n D ig ita l Inputs). I f the R U N c o m m a n d is on w h en c h a n g in g a n y o f these
settings, the m o to r m a y u n e x p e c te d ly start running, a n d c o u ld re s u lt in injury.
■ H1-03 to H1-08: Functions for Terminals S3 to S8
These parameters assign functions to the multi-function digital inputs. The various functions and their settings are listed
in
Table 5.9
.
No.
Parameter Name
Setting
Range
H1-03
Terminal S3 Function Selection
3 to 79
H 1-04
Terminal S4 Function Selection
3 to 79
H1-05
Terminal S5 Function Selection
3 to 79
H1-06
Terminal S6 Function Selection
3 to 79
H 1-07
Terminal S7 Function Selection
3 to 79
H1-08
Terminal S8 Function Selection
3 to 79
Default
Determined by d1-18 <1>
F: Through M ode
<1> With the speed reference priority d1-18 is set to 0 or 3, the default settings for param eters H1-03 to H 1-07 governing input terminals S3 to S7
are: 24, 14, 3, 4, and 5 respectively. W hen d1-18 is set to 1 or 2, the default settings for H1-03 to H 1-07 become 50, 54, 51, 53, and F
respectively.
Table 5.9 Multi-Function Digital Input Terminal Settings
Setting
Function
Page
Setting
Function
Page
3
Multi-Step Speed Reference 1
171
20 to 2F
External Fault
173
4
Multi-Step Speed Reference 2
50
Nominal Speed
174
5
Multi-Step Speed Reference 3
51
Intermediate Speed
174
6
Jog reference selection
171
52
Releveling Speed
174
7
A ccel/decel Ramp Selection 1
171
53
Leveling Speed
174
8
Baseblock Command (N.O.)
172
54
Inspection Operation
174
9
Baseblock Command (N.C.)
55
R escue Operation
174
F
N ot used (Through M ode)
172
56
Motor Contactor Feedback
174
14
Fault Reset
172
57
High Speed Limit Up
174
15
Emergency Stop (N.O.)
172
58
High Speed Limit D own
174
16
Motor 2 selection
173
5C
Stop Distance Correction
175
17
Emergency Stop (N .C.)
172
67
Communications Test Mode
175
18
Timer Function Input
173
79
Brake Feedback
175
1A
A ccel/decel Ramp Selection 2
173
-
-
-
Setting 3 to 5: Multi-Step Speed Reference 1 to 3
Switches multi-step speed frequency references d1-01 to d1-08 by digital inputs. Refer to
Speed Selection Using Digital
Inputs (b1-01 = 0) on page 106
for details.
Setting 6: Jog reference selection
When the speed reference is not assigned to the input terminals (b1-01 ф 1), then the Jog frequency will be activated
every time an input terminal set for the Jog frequency reference closes. Note that the speed reference priority selection in
d1-18 may disable the Jog frequency.
Table 5.10 Speed Reference Priority and Jog Frequency
d1-18 (Speed Reference
Selection Mode)
Jog Frequency
0
M ulti-speed references take priority, and the leveling speed in d1-26 is used for the Jog frequency.
Jog frequency cannot be used.
2
Jog frequency cannot be used.
3
M ulti-speed references take priority, and the leveling speed in d1-26 is used for the Jog frequency.
Setting 7: Accel/decel ramp selection 1
Switches between accel/decel times 1 (C1-01 and C1-02) and 2 (C1-03 and C1-04). Refer to
C1-01 to C1-08: Accel,
Decel Ramps 1 to 4 on page 144
for details.
YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual
171
P
a
ra
m
e
te
r
D
e
ta
il
s