54
YASKAWA
TOEPC710616134G AC Drive L1000A Technical Manual Addendum
Figure 6.21 Premature Termination DCP4
◆
DCP Fast-Stop Function
The Fast-Stop Function stops the motor with a dedicated Fast-Stop ramp. It can be used to position the car during
commissioning or as failure reaction after an identified malfunction. The electrical braking method is often faster
than stopping with mechanical brake.
The functionality is independent of operation mode DCP3 or DCP4.
■
Activation of the Fast-Stop Function
The control of the Fast-Stop Function is based on the Fast-Start function control.
The Fast-Stop function is activated using an additional speed mode command (DCP3: B3=1, B2=1, B1=1, B0=1;
DCP4: B3=1, B2=1, B1=0, B0=1) during the travel, applying speed VF (4h) in the data bytes.
Summary of Contents for L1000A CIMR-LC F Series
Page 1: ...AC Drive L1000A For Lift Applications Technical Manual Addendum Type CIMR LCxFxxxxxxx 913x Web...
Page 98: ...15 Appendix 98 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Page 99: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 99 EN...
Page 100: ...15 Appendix 100 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Page 101: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 101 EN...
Page 102: ...15 Appendix 102 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...