YASKAWA
TOEPC710616134G AC Drive L1000A Technical Manual Addendum
29
When the drive controller has received no or only a faulty initialization message ('I','0') from the lift controller, the
drive controller does not activate any travel sequence. When a travel start sequence is initiated nevertheless, the
Drive triggers a fault
DCE2
and forces a time-out of 1 second (Tx and Rx channels are cleared, Rx messages are
ignored for 1 second), and the lift controller must send a new initialization message.
Initialization Message from Lift Controller
Typically, the lift controller sends the inquiry after switching on/reset and disconnection (time-out).
Response Initialization Message from Drive Controller
The drive controller responds with the following message after receiving the lift controller's message.
Manufacturer Codes
Table 6.4 Lift Controller Manufacturers
Name
ID
Böhnke + Partner GmbH
BP
Kollmorgen Steuerungstechnik GmbH
KN
NEW LIFT Steuerungsbau GmbH
NL
Name
ID
OSMA Aufzüge, Albert Schenk GmbH & Co KG
OS
Schneider Steuerungstechnik GmbH
LI
Strack Lift Automation GmbH
ST
Table 6.5 Drive Controller Manufacturers
Name
ID
ABB Asea Brown Boveri Ltd
AB
Brunner & Fecher Regelungstechnik GmbH
BF
Bucher Hydraulics AG
BH
Control Techniques GmbH
CT
Danfoss GmbH
DA
Emotron Lift Center GmbH
DE
Fuji Electric GmbH
FE
Name
ID
Gefran Deutschland GmbH
SS
MagneTek (UK) Ltd.
MT
RST Elektronik GmbH
RS
Thyssen Krupp Aufzugswerke GmbH
TY
Venzke-DriveCon GmbH
VZ
Yaskawa Europe GmbH
YE
Ziehl-Abegg AG
ZA
Setting Up the Data-Information-Type ('I' '1')
By transmitting this message during the initialization phase, the following items are determined:
•
Whether the lift controller transmits the remaining distance in 15-bit or 16-bit mode
•
Whether the drive controller transmits the braking distance in 15-bit or 16-bit mode or not at all
•
Whether the drive controller transmits the Extended Status
•
Whether the drive controller alternately transmits the Extended Status and the 15 bit braking distance (for
DCP3, 0x00 is transferred for the braking distance)
•
Whether the drive's response message to the message ('I','9') is transmitted with or without additional
information
Data-Information-Type Message from Lift Controller
The lift controller sets up the kind of information in the data bytes while transmitting this message during
initialization.
STX
1C
'I'
'1'
Protocol Type
Data Information Type
ETX
Protocol Type "Extended Data Communication" :
EN
Summary of Contents for L1000A CIMR-LC F Series
Page 1: ...AC Drive L1000A For Lift Applications Technical Manual Addendum Type CIMR LCxFxxxxxxx 913x Web...
Page 98: ...15 Appendix 98 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Page 99: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 99 EN...
Page 100: ...15 Appendix 100 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Page 101: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 101 EN...
Page 102: ...15 Appendix 102 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...