Page 1: ...e Controller MP3000 Series INSTRUCTIONS MANUAL NO TOBP C880725 31B Model JEPMC YVD3001 E To properly use the product read this manual thoroughly and retain for easy reference inspection and maintenanc...

Page 2: ...of the information contained herein Moreover because Yaskawa is constantly striving to improve its high quality prod ucts the information contained in this manual is subject to change with out notice...

Page 3: ...eded could possibly result in loss of life or serious injury Indicates precautions that if not heeded could result in relatively serious or minor injury or property damage If not heeded even precautio...

Page 4: ...E 2 The following precautions are for storage transportation installation wiring operation maintenance inspection and disposal These precautions are important and must be observed...

Page 5: ...con nected to it may start operation suddenly Provide safety measures in advance to ensure human safety when operation restarts There is a risk of injury Do not touch anything inside the Machine Contr...

Page 6: ...e subject to excessive dust dirt salt or metallic powder Locations that are subject to water oil or chemicals Locations that are subject to vibration or shock There is a risk of fire electrical shock...

Page 7: ...are kiln dried to a core temperature of 56 C for 30 minutes or more If the electronic products which include stand alone prod ucts and products installed in machines are packed with fumigated wooden m...

Page 8: ...ve dust dirt salt or metallic powder Locations that are subject to water oil or chemicals Locations that are subject to vibration or shock There is a risk of fire electrical shock or device damage Nev...

Page 9: ...other devices There is a risk of fire or malfunction Do not subject the Machine Controller to strong shock There is a risk of malfunction Suitable battery installation must be performed and it must be...

Page 10: ...rotection against shorts in external wiring There is a risk of fire Provide sufficient shielding when using the Machine Controller in the following locations Locations that are subject to noise such a...

Page 11: ...distance Signal voltage Separate the I O signal cables for control circuits from the power cables both inside and outside the control panel to reduce the influence of noise from the power cables If th...

Page 12: ...failure or errors caused by external fac tors Shutdown of operation due to Machine Controller detection of an error in self diagnosis and the subsequent turning OFF or holding of output signals Holdin...

Page 13: ...ry or device dam age Do not forget to perform the following tasks when you replace the Vision Unit Back up all templates and parameters from the Vision Unit that is being replaced Transfer all saved t...

Page 14: ...ve guards Always replace the cover or protective guard as specified first and then operate the products in accordance with the manual The illustrations that are presented in this manual are typical ex...

Page 15: ...ty period above This warranty does not cover defects caused by the delivered product reaching the end of its service life and replacement of parts that require replacement or that have a limited servi...

Page 16: ...execution of the programs provided by the user or by a third party for use with programmable Yaskawa prod ucts The information described in product catalogs or manu als is provided for the purpose of...

Page 17: ...de safety mea sures to minimize hazards in the event of failure Outdoor use use involving potential chemical contamination or electrical interference or use in conditions or environments not described...

Page 18: ...safety of the actual devices and equipment to be used before using the prod uct Read and understand all use prohibitions and precau tions and operate the Yaskawa product correctly to pre vent acciden...

Page 19: ...13 1 Confirmations Upon Delivery 18 Nameplate 19 2 Installation 20 3 Wiring 22 4 Inspections 23 Daily Inspections 23 Periodic Inspections 24 Replacement Guidelines for Machine Controller Parts 25 5 EM...

Page 20: ...ce of purchase or your Yaskawa representative immedi ately Item Confirmation Method Have you received the correct Machine Controller as ordered Check the model number on the nameplate on the side of t...

Page 21: ...1 Confirmations Upon Delivery E 19 Nameplate Model number Version Serial number MAC address 0 106 3 8 4 1 vision...

Page 22: ...t temperature around the Machine Controller does not exceed 50 C If you install Machine Controllers side by side install a cooling fan above them Provide gaps above and below the Machine Controller In...

Page 23: ...fail in the future if exposed to cor rosive gas Others Do not install the Machine Controller in loca tions that are subject to high temperatures or high humidity or subject to excessive amounts of dus...

Page 24: ...3 Wiring E 22 3 Wiring Refer to the following manual for details on connecting the Machine Controller MP3000 Series Vision Unit User s Manual Manual No SIEP C880725 31...

Page 25: ...spection Item Description Criteria Correction Installation condition Loosescrews or covers All screws and covers must be secure Tighten the screws Connection conditions Loose termi nal screws Screws m...

Page 26: ...o 12 months Measure the temperature and humidity with a hydrometer and thermom eter and mea sure corrosive gas They must be within specifi cations Remove sources of contamina tion or improve the insta...

Page 27: ...g table Yaskawa will inspect your Machine Controller and determine if part replacement is required Yaskawa will initialize the settings of all parameters to the default values in Machine Controllers t...

Page 28: ...d EN 61000 6 4 However the Machine Controller is an electric device that is used as part of a machine or manufacturing equipment Therefore the EMC performance will also depend on the configuration of...

Page 29: ...Revision DANGER WARNING 1 Revision Nameplate 5 Addition EMC standard EN 61000 6 4 Back cover Revision Address January 2013 0 Safety Precautions Addition Precautions on battery installation Back cover...

Page 30: ...He Road HuangPu District Shanghai 200003 China Phone 86 21 5385 2200 Fax 86 21 5385 3299 http www yaskawa com cn YASKAWA ELECTRIC CHINA CO LTD BEIJING OFFICE Room 1011 Tower W3 Oriental Plaza No 1 Eas...

Page 31: ...Precautions for Korean Radio Waves Act A A...